                          waves+ Reference Guide
                          ----------------------

                        Entropic Research Laboratory

This is a reference guide to the commands and symbols in the waves+ package.
It essentially consists of the material in the ``Reference Guide'' part of
the waves+ Manual.  It covers language to be used to control xwaves and the
attachments; it will not go into detail about how to use the commands to
build your specific application or how to embed them in a standard setup.
For that type of information see the parts ``waves+ in Detail'' and ``The
Attachments'' in the full manual.

 Chapters

   26  xwaves command reference
   27  xwaves symbols reference
   28  xlabel reference
   29  xspectrum reference
   30  xmarks reference
   31  xchart reference

contain a comprehensive reference. Chapters

   32  xwaves quick reference
   33  xlabel quick reference
   34  xspectrum quick reference
   35  xmarks quick reference
   36  xchart quick reference

contain a quick reference to all symbols and commands, which are
alphabetical lists with symbols and commands and their parameters.

In the command references we make frequent use of terms like quoted string,
simple quoted string, boolean, etc. For the definition of these terms refer
to the glossary.

----------------------------------------------------------------------------

   26  xwaves command reference
       26.1  Introduction
       26.2  Global xwaves Commands
       26.3  Obsolete global commands
       26.4  xwaves object commands
   27  xwaves symbols reference
       27.1  Introduction
       27.2  Global symbols
       27.3  View-specific symbols
             27.3.1  Read-only (get only) object symbols
             27.3.2  Write-only (set only) View Symbols
             27.3.3  Read-Write (get or set) View Symbols
             27.3.4  Notes for display window specific symbols
   28  xlabel reference
       28.1  xlabel commands
       28.2  xlabel symbols
   29  xspectrum reference
       29.1  xspectrum commands
       29.2  xspectrum symbols
   30  xmarks reference
   31  xchart reference
   32  xwaves quick reference
       32.1  xwaves commands
             32.1.1  xwaves global commands
             32.1.2  xwaves object commands
             32.1.3  xwaves built-in commands
       32.2  xwaves symbols
             32.2.1  Global symbols
             32.2.2  Objebct symbols
   33  xlabel quick reference
       33.1  xlabel command reference
       33.2  xlabel symbols
   34  xspectrum quick reference
       34.1  xspectrum command reference
       34.2  xspectrum symbols
   35  xmarks quick reference
   36  xchart quick reference
       36.1  xchart command reference
       36.2  xchart symbol reference
   37  Glossary

----------------------------------------------------------------------------

Chapter 26

xwaves command reference

----------------------------------------------------------------------------

   26.1  Introduction
   26.2  Global xwaves Commands
   26.3  Obsolete global commands
   26.4  xwaves object commands

----------------------------------------------------------------------------

26.1  Introduction

There are five routes by which commands may be directed to xwaves:

  1. from xwaves command files.
  2. With the send_xwaves program from the UNIX command-line or from shell
     scripts.
  3. From an attached program (like xspectrum or xlabel).
  4. By way of the send_xwaves ESPS library call.
  5. By typing directly in the COMMAND (or @file): field in the Control
     Panel.

Regardless of the source, the syntax remains the same:

     object command [keyword value] [keyword value] ...

as described in the chapter ``The waves+ Command Language'' of the full
manual.

When commands are read from a xwaves command file, three special xwaves
commands can be used that can not used in other contexts: branch , call  and
return . Refer to their descriptions below.

Note that xwaves command files may be executed by xwaves at startup by
specifying one as the init_file in your profile file, as a file
specification on the xwaves command line, or after xwaves has started by
using the COMMAND or (@file): item (see the section ``The Main Control
Panel'' of the full manual) or via the send_xwaves  (1-ESPS) command. A UNIX
command for starting an xwaves command file with send_xwaves might look like
this:

     send_xwaves @file.WC

where file.WC is the ASCII file containing the command sequence.

The commands for xwaves are divided into two groups: the global commands and
the object commands. The global commands perform general functions in xwaves
not specifically directed at a particular display window or object. The
object commands have an effect on the selected object or display window
only.

----------------------------------------------------------------------------

26.2  Global xwaves Commands

The following commands and keyword/arguments may be directed to xwaves.
These are referred to as waves commands since the explicit or implicit
receiver of them is the xwaves-internal object named waves. If the first
word in a command does not match the name of any existing xwaves object,
waves is assumed, thus shortcutting the expression of commonly used
commands. Thus:

     set verbose 0

is exactly equivalent to

     waves set verbose 0

add_op
     DEFINE NEW XWAVES MENUS AND OPERATORS

     name
          A simple quoted string specifying the name of the new operator.
          This can be any ASCII string with embedded spaces as required. If
          the operator is being added to a menu, this is the string that
          will appear in the menu.
     op
          A quoted string specifying the operation to be performed. This
          operation can either be a command to be executed in a UNIX shell
          or an xwaves-internal command drawn from either the waves or
          object commands list. If the operation is an xwaves-internal
          command it must be preceded by a # sign. The keyword command is an
          exact synonym for op.
     menu
          The menu list in which the new operator is to be placed. The value
          is usually one of wave, spect, all or none, but can be any name
          you choose. The values wave, spect, and all cause the new operator
          to appear in the corresponding data display window menus. Any
          other name will prevent the operator from appearing in the menus,
          but will make it accessible to the key_map and op commands
          described below.

     The add_op command provides the primary means for specifying new object
     commands to be added to the xwaves command set. The operators may be
     added to the data display window menus or simply placed on lists
     internal to xwaves for access by other means, such as a keyboard
     bindings. Several examples of the use of add_op may be found in
     $ESPS_BASE/bin/test_waves. The syntax for the add_op command is an
     extended version of the standard syntax, with the following two
     extensions:
       1. symbolic access to xwaves state: Any string preceded by a
          non-alpha-numeric character and an underline (e.g. _name) is
          interpreted as an xwaves variable symbol and is evaluated at the
          time the added operator is invoked. Acceptable symbols include any
          of the display window-specific variables, any of the built-in or
          user defined global variables and the distinguished symbol out.
          (note that ``.'' is the last character of the symbol).

          The sequence _out. is interpreted at execution time as an output
          file name generation request. The name of the display window from
          which the operator was invoked is processed to take into account
          the output_dir  specification and then has an extension added to
          make its name unique. The out. symbol can, itself, have extended
          qualifiers, as follows:
             + out.g.[ext]

             + out.t.[ext]

             + out.n.[ext]

          The g. qualifier indicates that the output file should be
          displayed graphically by xwaves after the operation is complete.
          The t. qualifier means that the new file should be displayed as
          ASCII information in a text window. The n. qualifier or absence of
          any qualifier means that xwaves is not to display the new file.
          The optional ext is a filename extension that you would like
          appended to the other name components. If ext is omitted, xwaves
          uses the extension ``.out'' added to the name of the input name of
          the file in the current display window. Subsequent file name
          generation requests results in insertion of sequence numbers
          before the extension .out. The out. symbol may be used any number
          of times in a given add_op command; each instance will result in
          the generation of a unique name. As files are generated by
          execution of the new command, their names are added to the ``new
          files'' list. They may be browsed by right mousing the OUTPUT
          file: main control panel item.

          It is possible to prepend and append some special characters to
          the symbol references. For a description see the section ``Using
          Symbols in the add_op Command'' of the full manual.
       2. Access to xwaves commands or other UNIX processes:

          If the first character in the command specification is the #
          character, the command will be interpreted as an internal waves
          command drawn from either the waves_commands or the
          object_commands list. Commands not preceded by the # will be
          executed by a UNIX shell.

          Except for xwaves symbol-value substitution described above, any
          text strings to be interpreted as UNIX commands are passed through
          unmodified. Thus, several UNIX processes on a pipe or sequences of
          semicolon-separated UNIX commands are permitted. The output file
          specifications described above, may appear anywhere in the op
          value.
     A simple add_op command to create a menu item that will play (D/A
     convert) the data from the left edge of the window to the cursor
     position might look like this:

          add_op name "LEFT PLAY" op # _name play \
              start _view_start_time end _cursor_time


     As a more interesting example, we will demonstrate the use of the
     add_op command to implement a sorting operator using a combination of
     UNIX and ESPS utilities. This operator will sort the samples in a
     one-dimensional signal according to increasing value and then create a
     new ``signal'' consisting of the sorted samples. Put the following in a
     file and execute it as a waves command file by typing @filename into
     the COMMAND (or @file): item of the xwaves main control panel. Put the
     whole add_op command on a single line and DO NOT include the backslash
     (\) line continuation characters.

          add_op name sort menu wave op copysd \
             _range_samp  _file - | pplain - | sort -n | \
             testsd -r `echo _r_marker_samp - \
             _l_marker_samp | bc` -a - _out.g.


     This creates the item sort on a waveform menu. It works like this:
     copysd  extracts the segment delimited by the left and right xwaves
     markers. pplain  converts the signal to an ASCII representation. The
     UNIX sort orders the samples numerically. testsd  is used to convert
     the sorted samples back into an ESPS sampled data file. Note that the
     sample rate argument to testsd (-r) is adjusted to normalize the
     ``duration'' of the sorted samples to unity by setting the rate equal
     to the number of samples sorted. The UNIX ``desk calculator'', bc is
     used to compute the number of samples based on the left and right
     marker positions. To use this new operator, position the left and right
     markers on a waveform display window to delimit a second or so of the
     signal. Then select the sort item from the display window menu.

     It is also possible to define operators as composed xwaves command,
     i.e. multiple xwaves commands in a row. You need to separate them with
     a double colon (::). See also the description of the send_xwaves
     command for precautions when using add_op with send_xwaves.

     Here is a rather complex example, that also shows how symbols can be
     used as commands. It is worthwhile to spend some time on this example
     to get a good understanding of both add_op and the command language in
     general:

          add_op name magnify menu none \
             op # set res_mag "_name set file _file \
             chan _cursor_channel plot_max _plot_max \
             plot_min _plot_min:: \
             _name bracket file _file \
             start _view_start_time end _view_end_time:: \
             _name set file _file \
             l_marker_time _l_marker_time \
             r_marker_time _r_marker_time":: \
             _name set file _file \
             chan _cursor_channel plot_max _t_marker_yval \
             plot_min _b_marker_yval:: \
             _name bracket file _file \
             start _l_marker_time end _r_marker_time
          add_op name restore_mag menu none op #_res_mag
          key_map key m menu wave op magnify
          key_map key M op restore_mag


     (NB: Backslashes at the end of lines in the last example only mean that
     the text is continued on the next line. Don't use backslashes in the
     COMMAND (or @file): field; just type all the following text on a single
     line.)

     The first add_op command defines the operator magnify, which is not on
     any menu. This operator executes a complex xwaves command. Its
     operation consists of three ``simple'' commands:
       1. defines a symbol res_mag, that contains a three-part complex
          command as its value. If executed, res_mag resets the symbols
          plot_max and plot_min to the values they had before the
          magnification was executed, it resets the view borders, and it
          resets the markers.
       2. sets the range of the plot to the range between the top and bottom
          marker (the horizontal marker lines).
       3. sets the view to contain the signal segment between the left and
          right marker.
     The second add_op command creates an operator restore_mag that executes
     the value of the symbol res_mag, which is set at each execution of
     magnify. The following two commands bind these two operators to keys.

add_op_panel
     GUI INTERFACE TO THE ADD_OP COMMAND

     help_file
          The name of an ASCII file explaining the use of the add_op panel.
          This file is displayed in response to a press of the Help button
          on the add_op panel. If help_file  is omitted, a useful help file
          will be made available.
     loc_x, loc_y
          The X and Y pixel coordinates desired for the upper left corner of
          the add_op panel. Reasonable defaults will be used if either of
          these is omitted.
     show_vars
          A boolean that determines if the lists of variable names should
          automatically be displayed when the add_op panel is created.
     show_ops
          A boolean that determines if the list of available display window
          commands should automatically be displayed when the add_op panel
          is created.

     The add_op_panel command creates a handy graphical interface to aid in
     building custom xwaves operators via the add_op command. When opened,
     the main add_op_panel displays the following items:
     operation name:
          This corresponds to the name keyword of the add_op command. The
          command must be named, so you need to enter the name here. Any
          ASCII string is acceptable. You need not quote names with multiple
          words.
     add_to_windows
          These two buttons determine which, if any, display window menus
          the new operation will appear on. If neither of these buttons is
          depressed, the new item will be on the none list, meaning it will
          be available for mapping to keys and for access by other means,
          but will not appear on any display window menus.
     show variables...
          This button opens another panel that displays two scrollable lists
          of xwaves global symbols and display window-specific symbols that
          may be used as components in add_op commands. It also permits
          specification of output file names.
     show commands...
          This button opens a panel providing access to the list of object
          commands and their keyword lists.
     Enter command...
          This text window is the area in which the add_op command will be
          constructed. You may type any or all of the components of an op
          value for an add_op command into this window. In many cases, you
          do not actually need to type, since selecting items from the
          scrollable lists in the variables and commands panels
          automatically adds them to the string being constructed at the
          current cursor location.
     Apply add_op
          Causes the add_op command to be executed with the components you
          have just constructed. Immediately after you Apply, you can use
          the new operation.
     Help
          Invokes a text window explaining the add_op command and the
          add_op_panel.
     Dismiss
          Closes the add_op_panel, but does NOT cause the add_op under
          construction to be installed. If you Dismiss without Apply first,
          the add_op being constructed will be lost and ignored.

     As an example, we will describe step-by-step the use of the add_op
     panel to construct a command to set the vertical display limits of a
     file to the current horizontal marker locations (vertical bracket
     markers). We assume the add_op panel is open.
       1. Left mouse the operation name: item and type in a name for the
          command: e.g vbracket.
       2. Press the show commands... and show variables... buttons.
       3. Press the current object button in the commands panel. Select the
          set command from the Commands: list.
       4. Select file from the Command attributes: list.
       5. Select file from the View-Specific Variables: list.
       6. Select plot_max from the Command attributes: list.
       7. Select t_marker_yval from the View-Specific Variables: list.
       8. select plot_min from the Command attributes: list.
       9. Select b_marker_yval from the View-Specific Variables: list.
      10. Be sure the waveform button is in, and the image button is out.
      11. Press the Apply add_op button.
     As you become more familiar with xwaves and the add_op command, you may
     prefer to to issue the command directly (or via send_xwaves). The
     direct xwaves command to create the vbracket menu item might look like
     this:

          add_op name vbracket menu wave op \
             # _name set file _file plot_max  _t_marker_yval \
             plot_min _b_marker_yval


     Note, however, that whether or not the the add_op_panel is routinely
     used to create operators, it can still serve as a quick interactive
     reference to xwaves commands, command argument names, and variable
     symbols.

add_waves
     RESTORE (OR ADD) AN ITEM TO A DATA DISPLAY WINDOW MENU

     name
          a quoted string to be used as an entry in xwaves menus.
     menu
          one of the strings wave, spect, and all. This indicates whether
          the new item is to be added only to the menu for waveform windows,
          only to the menu for spectrogram windows, or to both menus. The
          default is all.
     op
          any named operator on the spect, wave or all menu-operator lists.
          This includes the built-in operators that are compiled into xwaves
          and any operators you have added with the add_op command. Note
          that the name of the menu-operator list containing the operator
          must be all or the same as the menu name specified to the
          add_waves command. See the chapter ``Data Window Menu Items'' of
          the full manual for discussions of the built-in menu items. The
          built-in Button Modes item is not an acceptable op.
     submenu
          identifier of a submenu to be added to the menu. In the current
          version, only the standard Button Modes  pull-right menu can be
          added as a submenu. For example, the command:

               add_waves submenu buttons


          will add the Button Modes, if one is not already present, to both
          window menus. The submenus for the waveform window menu and the
          spectrogram window menu are different; the appropriate submenu is
          added to each menu. The keyword menu can be used to restrict the
          operation to a specific menu. The keyword name can be used to make
          the added item appear with a name other than Button Modes. The
          argument of the submenu keyword, shown above as buttons, must be
          present for consistency with command syntax, but the value is
          ignored in the present implementation, submenu foo would do just
          as well. In a future extension of xwaves, the argument may be used
          to distinguish among different submenus to be added to a menu.
     command
          an arbitrary quoted string (may contain blanks) that is executed
          as an xwaves command when the new menu item is selected. So this
          may not be a UNIX command. The keywords command, builtin, and
          submenu are mutually exclusive. This means of adding a new command
          to menus by use of add_waves is now considered obsolete. See the
          add_op command.

     The command that is specified with the op option of the add_waves
     command is added to one or both of the xwaves window menus. Thus an
     item that has been removed with either the delete_item  or
     delete_all_items  command can be restored to a menu. In fact this
     should be the main function of add_waves .

     If name is specified, the function will be identified in the menu by
     that name, rather than by the string in the menu-operator list. The
     keywords command, op, and submenu are mutually exclusive. In the
     context of the add_waves command, builtin is an exact synonym for the
     op keyword.

attach
     ATTACH A FUNCTION

     function
          the name of the desired function (e.g. xspectrum or xlabel.)

     Several attachments may be active simultaneously. If more than one
     invocation of a given attachment is to be active at a time, create
     alternate names for the attachment that are symbolically linked to the
     same executable and refer to these names when creating the extra
     invocations.

branch
     TRANSFER CONTROL TO ANOTHER xwaves COMMAND FILE

     commandname
          the path name of the new command file. No return to the original
          command file is possible (although it may be branched to). The
          branch command provides a means for chaining together command
          files.

     The call, branch, and return xwaves commands are only used in xwaves
     command files. They are of no use as direct commands. Before writing a
     new xwaves command file, consider using a UNIX shell script with
     send_xwaves , instead.

call
     CALL AN xwaves COMMAND FILE AS A SUBROUTINE

     commandname
          the path name of the subroutine command file. There is currently
          no mechanism for argument passing other than mutually agreed-upon
          use of xwaves global symbols or the UNIX file system.

     The call, branch, and return xwaves commands are only used in xwaves
     command files. They are of no use as direct commands. Before writing a
     new xwaves command file, consider using a UNIX shell script with
     send_xwaves, instead.

cd
     CHANGE WORKING DIRECTORY

     path
          the new working directory. Subsequent relative file names passed
          to xwaves are interpreted relative to this directory. Path must be
          specified.

close_ctlwin
     CLOSE (ICONIZE) MAIN CONTROL PANEL

     invisible
          This boolean if set to 1 makes the view completely invisible. So
          there no icon left on the screen.

     The main xwaves control panel is closed down to an icon. Note that the
     global ctlwin_iconized  can be used to start xwaves in this state.

close_panel
     CLOSE AUXILIARY CONTROL PANEL

     name
          contiguous string of non-blank characters that has been used in
          creating an auxiliary control panel with the make_panel  command.
          The named panel is closed (i.e. iconized).
     invisible
          This boolean if set to 1 makes the view completely invisible. So
          there no icon left on the screen.

delete_all_items
     REMOVE EVERYTHING FROM xwaves MENUS

     menu
          one of the strings wave, spect, and all. This indicates whether
          the new item is to be removed only from the menu for waveform
          windows, only from the menu for spectrogram windows or from both
          menus. The default is all.

     All items are removed from the specified menus. Note that the
     underlying operator definitions are not affected, so the named
     menu-operator lists may still be accessed for key_map, save_add_ops,
     op, etc.

delete_item
     REMOVE ITEM FROM xwaves MENUS

     name
          a quoted string that exactly matches an entry in the data display
          window menu(s).
     menu
          one of the strings wave, spect, or all. This indicates whether the
          new item is to be removed only from the menu for waveform windows,
          only from the menu for spectrogram windows, or from both menus.
          The default is all.

     The named item is removed from any of the specified menus in which it
     occurs. As with delete_all_items, the underlying operator definition in
     the menu-operator list(s) is not affected.

detach
     DETACH ANY FUNCTION CURRENTLY ATTACHED TO xwaves

     function
          the name of the function to detach. If the function specification
          is omitted, all attachments will be detached.

enable_server
     START LISTENING FOR COMMANDS ON SOCKET

     xwaves starts listening for commands on an INET domain socket port. The
     port number used is determined in the following order:
       1. the global socket_port as specified in the .wave_pro file or by a
          direct set command. Setting this global has no effect if xwaves is
          already operating as a display server (e.g., if it was started
          with -s), but it determines the socket number used the next time
          server mode is started by enable_server;
       2. the port specified by the command line option -p;
       3. the contents of the UNIX environment variable WAVES_PORT  at the
          time xwaves starts;
       4. a compiled-in default.
     Note that as of version 5.0, the socket-based ``server mode'' is only
     used in conjunction with the send_xwaves  (3-ESPS) library functions,
     not with the send_xwaves  program. In future releases, the
     enable_server and disable_server commands may be eliminated since they
     will be unnecessary.

get
     GET GLOBAL ATTRIBUTES FROM xwaves

     attributes
          This optional keyword has only one meaningful value at this time:
          global . If global is specified, the data is provided as
          keyword-value pairs suitable for output into a file that may then
          be used as an xwaves profile file (.wave_pro). Otherwise, only the
          variable values explicitly requested are returned (without their
          corresponding keywords).
     output
          the name of an output file to receive keyword- value pairs (in a
          format suitable for a .wave_pro file) in the case where global is
          specified for attributes or an unadorned list of values if
          attributes is not specified.

          If an output is not specified, but attributes is, then stdout is
          assumed. If attributes is not specified the values ONLY go to an
          output file or the calling process (e.g. send_xwaves). The output
          name can include UNIX environment variables (e.g., $HOME).
     aname
          a quoted string list of xwaves globals to output, in the case
          where global is specified for attributes. If aname is omitted, but
          attributes global is specified, all global values are output. If
          attributes is not specified, aname (and an associated list of
          symbols) must be specified.

     Note that the keywords return_id, file and function are recognized by
     the get command, but are for xwaves-internal use only. See also the get
     command in the section 26.4.

key_map
     BIND A KEYBOARD CHARACTER TO AN OPERATOR

     op
          a quoted string value that is the exact name of the operator to be
          called when the key is struck. This operator name may be drawn
          from any of the built-in menu operations (see the chapter ``Data
          Window Menu Items'' of the full manual) or may be any operator
          defined with the add_op command. The keyword command is an exact
          synonym for op.
     menu
          the display window type for which the mapping is to be effective.
          Typical values for menu would be wave, spect or all, but any menu
          list created with the add_op command may be accessed. If no menu
          is specified, all lists (including new lists created by the add_op
          command) will be searched and the first operator with the
          requested name will be applied to all display window types.
          However, add_ops and built-ins specifically designated as wave or
          spect operator will not cross over and be mappable to other than
          this designated view type.
     key
          The single character that is to be mapped to the operator. All
          alphanumeric keys and control keys are acceptable values. Control
          qualification is indicated by preceding the key with the caret (^)
          symbol. The space bar is represented by the underline character
          (_). If desired, the same key can be made to have different
          semantics in the different display window types through use of the
          menu specification.

     As an example, suppose you wanted the space bar to play between marks
     in the spectrogram windows, but apply marks in the waveform window. The
     following key_map and add_op commands would do the trick:

          add_op name mark menu wave op # _name mark \
             time _cursor_time
          key_map key _ menu spect op play between marks
          key_map key _ menu wave op mark


key_unmap
     REMOVE A KEY-TO-OPERATOR BINDING

     menu
          the name of the display window type (spect, wave or all) from
          which the key-mapping is to be deleted. If unspecified, all is
          assumed. Note that menu is a bit of a misnomer, it should probably
          be called something like view_type.
     key
          The character that is to be unmapped. This is specified the same
          as for the key_map command.

     Note the key_unmap command does not affect the definition of the
     operator, only its binding to a key. If a key is to be remapped to
     another operator it is not necessary to perform a key_unmap first.

kill
     DESTROY ONE OR MORE DATA DISPLAY WINDOWS

     <none>
          implies that all display objects are to be killed.
     name
          name of the display object with a display window to be killed.
     file
          the specific data display window to be killed. If file is
          specified, name must be specified. If name is specified and file
          omitted, all objects in the named display object will be killed.
          Note that the file name specified must match the name by which the
          display window was created (which may not be the name displayed in
          the display window's frame if the global shorten_header is
          enabled).

kill_panel
     KILL AUXILIARY CONTROL PANEL

     name
          contiguous string of non-blank characters that has been used in
          creating an auxiliary control panel with the make_panel command.
          The named panel ceases to exist.

make
     CREATE A DATA DISPLAY WINDOW AND/OR DISPLAY OBJECT

     name
          any contiguous string to be used as an object name. If omitted,
          the current object name is used.
     file
          the filename of some data to be displayed. If name is omitted and
          file is specified, the simplified base name of the first file will
          become the object name.
     identifiers
          a quoted string of vector elements to display by name (see also
          activate in section 26.4).
     numbers
          a quoted string of vector elements to display by number (from
          zero) (see also activate in the section 26.4).
     <any xwaves global symbol>
          as described for the xwaves set command (including new
          definitions). The effect (with an exception noted below) is to set
          the named global. The globals that pertain to display window
          attributes will be used with any new values assigned in the
          current and all subsequent display window creations, unless they
          are otherwise modified. A few of the more commonly used variables
          have been given aliases for convenience:
     duration
          (alias for ref_size).
     start
          (alias for ref_start).
     loc_x
          (alias for first_x).
     loc_y
          (alias for first_y).
     width
          Using this keyword sets the width of the new display window (for
          both waveforms and spectrograms). The keyword is not an alias, so
          no corresponding global is set. In the case of waveform windows,
          using wave_width has the same effect but also sets the
          corresponding global and hence affects subsequently created
          display windows.
     height
          Using this keyword sets the height of the new display window (for
          both waveforms and spectrograms). The keyword is not an alias, so
          no corresponding globals is set. In the case of waveform windows,
          using wave_height has the same effect, but also sets the
          corresponding global.
     def_header
          See the description of the the global symbol def_header. This sets
          the global variable.

     The make command is the primary means for other programs to create data
     display windows in xwaves. It permits simultaneous specification of all
     major display window attributes and the naming of display object. For
     example, if a UNIX shell script is to display some data using xwaves,
     it could use the program send_xwaves like this:

          send_xwaves make name myview file my_data.sd \
             loc_x 0 loc_y 200 ...


     where ``...'' indicates any additional display window attributes you
     may need to specify as keyword-value pairs on the same command line.
     Later, you may want to send commands to this object. Suppose you wanted
     to iconize (close) the display window containing my_data.sd:

          send_xwaves myview close file my_data.sd


make_panel
     CREATE AUXILIARY CONTROL PANEL

     loc_x
          integer. Distance in pixels of the left edge of the panel from the
          left edge of the screen.
     loc_y
          integer. Distance in pixels of the top of the panel from the top
          of the screen.
     title
          identifying quoted string to be displayed in the panel frame.
     icon_title
          identifying quoted string to be displayed as the title of the
          iconized panel.
     columns
          the number of buttons in each row of the panel (default is 10).
     quit_button
          if non-zero, causes a QUIT button to be included as the first
          button in the panel. The default is 0 (no quit button). If the
          UNIX environment variable BBOX_QUIT_BUTTON  is defined, this
          results in a QUIT button being added even if quit_button is 0. The
          resulting behavior is somewhat different from the case where
          quit_button is non-zero, however, in that the QUIT button is
          created in a row by itself at the top of the panel and is not
          counted with the other buttons when determining where to break the
          first row. The reason for this is to avoid disturbing the geometry
          that may have been selected carefully by the application calling
          make_panel. The main reason for providing global control via
          BBOX_QUIT_BUTTON is to facilitate usage on systems with window
          managers that do not provide an independent means for killing
          windows.
     name
          contiguous string of non-blank characters. This string is used
          internally by other xwaves commands in referring to the panel.
          (Cf. close_panel, open_panel, kill_panel.) If the name is in use,
          the existing panel is destroyed.
     file
          contiguous string of non-blank characters forming a valid
          filename. This names an olwm -format ASCII menu file that defines
          the layout of the panel, the names of its buttons and the xwaves
          commands they perform. By default, xwaves looks for the named file
          first in the current directory and then in
          $ESPS_BASE/lib/waves/menus. This default path can be overridden by
          setting the UNIX environment variable WAVES_MENU_PATH . For a
          discussion of the format of the menu files see mbuttons  and
          exv_bbox . For examples, look at the files
          $ESPS_BASE/lib/waves/commands/*.WC.
     panel_choice
          a boolean that, when enabled, causes the items comprising the
          menus under the panel buttons to be expanded as exclusive
          pushbuttons on the panel, rather than as pull-down menus, which is
          the default.
     choice_horiz
          if panel_choice is enabled, choice_horiz is a boolean that
          determines the orientation of the button layout, which is vertical
          by default.

open_ctlwin
     OPEN MAIN CONTROL PANEL

     If it is currently iconized, the main xwaves control panel is opened.
     Otherwise, there is no effect.

open_panel
     OPEN AUXILIARY CONTROL PANEL

     name
          contiguous string of non-blank characters that has been used in
          creating an auxiliary control panel with the make_panel  command.
          The named panel, if closed (that is, iconized) is opened.

print_setup
     START PRINT GRAPHIC SETUP PANEL

     This command invokes a panel that can be used to set the various
     globals that affect printing and saving of graphic images. See the
     chapter ``Printing Graphics'' of the full manual.

quit
     CAUSES xwaves TO QUIT AND RETURN TO UNIX

     This commands stops xwaves. Any modified signals will be saved. All
     attachments will be stopped. The xwaves license will be released before
     xwaves exits.

return
     RETURN TO THE CALLING WAVES COMMAND FILE

     In addition to its use as a means for returning from subroutines, the
     return command may be placed at the end of any command file to force
     the removal of the file's name from the COMMAND (or @file): main
     control panel line on completion of the file.

     The call, branch, and return xwaves commands are only used in xwaves
     command files. They are of no use as direct commands. Before writing a
     new xwaves command file, consider using a UNIX shell script with
     send_xwaves , instead.

save_add_ops
     SAVE ALL CURRENT CUSTOM OPERATOR DEFINITIONS

     output
          the name of a file into which the add_op and add_waves definitions
          should be written.

     save_add_ops writes a series of add_op commands to the output file that
     may be executed as an xwaves command file to reconstruct the current
     custom-made operator set. The last line in the file is the xwaves
     return command, so the file can be call ed as part of an initialization
     script. All operators created with add_op, add_espsf, add_espsn,
     add_espst and add_waves are saved.

save_keymaps
     SAVE ALL CURRENT KEY-TO-OPERATOR BINDINGS

     output
          the name of a file into which the key bindings should be written.

     save_key_map writes a series of key_map commands to the output file
     that may be executed as an xwaves command file to reconstruct all of
     the current key-to-operator bindings. The last line in the file is the
     xwaves return command, so the file can be call ed as part of an
     initialization script. Note that the operators referred to by the
     key_map command must actually exist at the time the mapping is per
     formed. Thus, the saved operators should be restored before executing
     the key-map save file.

save_menus
     SAVE THE CURRENT DISPLAY WINDOW MENU CONFIGURATION

     output
          the name of a file into which the menu definitions should be
          written.
     menu
          the display window type of the menu that is to be saved.
          Acceptable values are spect, wave and all. If unspecified, all is
          assumed.

     save_menus writes a series of add_waves  commands to the output file
     that may be executed as an xwaves command file to reconstruct the
     current menu configuration that might have been established by a series
     of add_op, add_waves, delete_item and other commands. Note that the
     first line in the output file is a delete_all_items command that clears
     all menus before building those specified in the balance of the file.
     Thus, if the union of multiple save_menus commands is required, the
     first line in all but the first one executed should be deleted. The
     last line in the file is the xwaves return command, so the file can be
     call ed as part of an initialization script.

save_panels
     SAVE ALL AUXILIARY PANEL SPECIFICATIONS

     output
          the name of a file into which the panel configuration information
          should be written.

     save_panels writes a series of make_panel  commands to the output file
     that may be executed as an xwaves command file to reconstruct all of
     the xwaves auxiliary button panels. The last line in the file is the
     xwaves return command, so the file can be call ed as part of an
     initialization script.

send
     SEND A MESSAGE TO THE FUNCTION(S) ATTACHED TO xwaves

     function
          The name of the attachment to receive the message. This should
          correspond to the name used to start the attachment, either via
          one of the main control panel Attach: buttons, or some other
          means. This MUST be the first keyword.
     registry
          The name that the attachment has registered with the X server for
          communications as. In most cases, this is simply the name of the
          program, but it might have been changed to be unique. When an
          attachment registeres with xwaves it sends its registry name.
     op
          a quoted string which is the actual string that is to be sent to
          the attachment, including the command receiver (the program name
          or a display object name) as the first item. The syntax of these
          send commands is the same as that for xwaves commands:

               object command [keyword value] [keyword value] ...


          For details of the available commands, see the manual sections for
          the individual attachments.

     As an example, suppose only the attachment xlabel were attached and you
     wanted to create a new label file attached to the xwaves display object
     named buddy, with a signal named buddy.sd. The following two commands
     would accomplish the same thing:

          send make name buddy signal buddy.sd \
             file buddy.lab color 125
          send function xlabel op xlabel make name buddy \
             signal buddy.sd  file buddy.lab color 125


     If several attachments were active, the second form could still be used
     meaningfully, but the first form could not. The first form is supported
     to retain compatibility with old waves+ scripts and to provide simple
     syntax for simple cases.

set
     ASSIGN VALUES TO GLOBAL SYMBOLS

     <any global variable name>
          arguments to the set command are always symbols and values to be
          assigned to them. Any of the built-in symbols (e.g. those defined
          in the master profile file in $ESPS_BASE/lib/waves/.wave_pro) may
          be assigned values. Refer to the master profile file or to chapter
          27 for a description of the built-in symbols, their meaning and
          their value type. Several assignments may be made per set command.
          The overall length of the set command and its assignment list
          should be limited to 500 characters.

          A feature new to the set command with version 5.0 is its ability
          to CREATE new symbols. Symbol creation uses exactly the same
          syntax as assignment of values to existing symbols:

               set new_symbol <any value>


          where new_symbol is any name you choose that does not conflict
          with existing symbol names and <any value> is a simple quoted
          string type (i.e. any string, either enclosed in quotes or not).
          Note that xwaves doesn't attach any meaning to the new symbol, but
          does provide access to it via the get command and through symbol
          substitution in add_op commands. New symbols may also be defined
          at will in the xwaves profile file.

          The meaning of many of the global variables is changed as of
          xwaves Version 5.0. This is due to the introduction of data
          display window specific attribute setting (see the set command in
          section 26.4.) Most global attributes that might reasonably be
          varied on a window-by-window basis, can now, in fact, be set
          specific to a display window. The ``global'' counterparts, usually
          with the same or similar name, are now used to establish default
          values for the creation of new display windows. Thus, setting
          these globals will usually result in no change in existing display
          windows.
     all
          any non-null string with no embedded spaces. The all symbol
          provides a means for globally setting variables that may now be
          assigned on a window-by-window basis. If all is assigned a value
          (any value), the symbols that are set with the current set command
          will be changed or set in all display windows (existing and
          future). For example, if the command:

               set middle_op blow up time


          were given as shown, the xwaves global would be set as directed,
          but existing display windows would not have their middle button
          operation changed. Any subsequently created display windows would,
          however, assume the new setting for middle_op. On the other hand,
          if the command were given as:

               set all t middle_op blow up time


          Then all existing and future waveform display windows would have
          the new value for middle_op.

setenv
     SET OR CREATE AN ENVIRONMENT VARIABLE

     variable
          The name of an environment variable to be set of created.
     value
          Value of the variable, which is a quoted string.

     This variable definition will be put into xwaves's UNIX environment so
     that any sub processes will inherit the new setting.

shell
     SEND COMMANDS TO A UNIX SHELL

     <any UNIX command line>
          command to be executed as a Bourne shell command under UNIX.

sleep
     SLEEP WHILE BACKGROUND PROCESS OCCURS

     seconds
          number of seconds xwaves is to sleep (0.2 sec resolution).

     When the results of display-setup operations in a xwaves command file
     are to be used (e.g. for screendumps), it may be necessary to issue at
     least a brief sleep command to allow the window system to actually
     execute the plot. This was necessary in xwaves prior to version 5.0,
     but is now rarely needed. When commands are sent to xwaves from
     send_xwaves , process synchronization is automatically taken care of,
     so no sleeps are necessary, unless it is convenient for some human
     factors reason, such as allowing a D/A operation to complete.

----------------------------------------------------------------------------

26.3  Obsolete global commands

The following four commands, listed with their keywords, are now considered
obsolete. They are still implemented in xwaves version 5.0, but may be
eliminated in future releases. Their function has been subsumed by the
add_op command. If you have scripts, etc. that use these commands, you can
see the mapping between them and add_op by simply issuing a save_add_ops
command after you run your script. xwaves will translate your commands to
add_op commands.

add_espsf
     ADD EXTERNAL ESPS-TO-FILE CALL TO xwaves MENUS

     out_ext
     display
     outputs
     name
     op
     command
     menu

add_espst
     ADD EXTERNAL ESPS -TO-TEXT CALL TO xwaves MENUS

     name
     op
     command
     menu

add_espsn
     ADD EXTERNAL ESPS (NO OUTPUT) CALL TO xwaves MENUS

     name
     op
     command
     menu

auto_plot_limits
     SET AUTOMATIC PLOT LIMITS

     This command just sets the xwaves globals plot_max and plot_min to 0.
     Thus, it provides a convenient means of returning to automatic plot
     scaling. It is considered obsolete, since individual control of plot
     scaling on a per-window basis is now available. It is still supported,
     but will probably be dropped in future releases. It is exactly
     equivalent to

          set all t plot_max 0 plot_min 0


----------------------------------------------------------------------------

26.4  xwaves object commands

The following commands and keyword/arguments may be sent to display objects
(as named in the make command). These are referred to variously as object
commands and object commands. The primary thing to keep in mind is that some
display window must already have been created before these can be sent and
that they are sent to a display object, rather than to the distinguished
object waves, the object name for the xwaves program.

Please note the definitions of quoted string and simple quoted string in
chapter 27. These two argument types are used heavily in the command
descriptions below.

activate
     ENABLE/DISABLE PLOTTING OF SELECTED ELEMENTS

     file
          full name of displayed signal (mandatory).
     op
          operation to be performed (set, clear or add; set is default). set
          means to display only those items specified by numbers or
          identifiers, clear means to remove the items (possibly leaving
          others shown), and add means to display the items (in addition to
          those already shown).
     numbers
          a quoted string list of integers: the element numbers to be
          effected.
     identifiers
          a quoted string list of FEA field names (or channel identifiers in
          the case of SIGnal files). Note: numbers or identifiers are
          mutually exclusive keywords.

     Channels that are activated are the channels returned by the display
     window symbol view_channels (see section 27.3). Note that activate may
     also be used to enable or disable traces overlaid on other display
     windows.

align
     ALIGN ALL DISPLAY WINDOWS IN A DISPLAY OBJECT

     file
          full name of the signal whose display is to serve as the model for
          other displays. If omitted, the most recently created display
          window is used as a model. Note that display windows will only
          rescale the time base if the attribute h_rescale is enabled. See
          h_rescale and h_spect_rescale in section 27.2.

bracket
     CHANGE DISPLAY WINDOW STARTING TIME AND TIME SCALE

     file
          full path name of signal whose display window is to be changed.
          (default is current INPUT file:)
     start
          time to correspond to left window edge (sec; defaults to left
          marker).
     end
          time to correspond to right window edge (sec; defaults to right
          marker).

     This command corresponds to the bracket markers waveform menu item. It
     has the side effect of placing the marker at the brackets limits.

close
     CLOSE A DATA DISPLAY WINDOW AND TURN INTO AN ICON

     file
          full name of the displayed signal to be closed. If two display
          windows of the same file are opened in the selected object, only
          the last opened display window can be iconized. Performs the same
          operation as the window system's close.
     invisible
          This boolean if set to 1 makes the view completely invisible. So
          there is no icon left on the screen.

colormap
     CHANGE THE COLORMAP USED FOR SPECTROGRAMS

     file
          the name of the display to be modified. This keyword and its
          argument have no effect. It is obsolete.
     threshold
          level (dB) below which spectral densities are white (see
          image_clip) in halftone plotting.
     range
          dB from start to end of current colormap or from saturated black
          to saturated white in dithered, monochrome images (dynamic range;
          see image_range).
     image_clip
          An alternative way to specify the clipping limit. Either threshold
          or image_clip may be specified. They are related by the equation:
          threshold = 105 - image_clip - image_range.
     image_range
          same as range. Note that the colormap command actually affects the
          global colormap of xwaves and is not specifiable on a
          window-by-window basis. This really should be a waves command.

cursor
     MOVE THE TIME/FREQUENCY CURSOR

     time
          the desired time location for the cursor (sec).
     yval
          the desired ordinal location for the cursor. In a spectrogram
          display window, this would correspond to the frequency in Hz.
          frequency is an exact synonym for yval in this context.

     See also the display window set command and the cursor_time  and
     cursor_yval  object symbols.

get
     GET ANY ATTRIBUTES FROM xwaves

     attributes
          Currently recognized arguments are global  and view . These
          determine the mode in which get, as an object command, functions.
          If global is specified, the get command operates exactly as
          described under get in section 26.2. (Note that in this mode, the
          results are represented as keyword-value pairs and are ONLY output
          to a specified output file or to xwaves' standard output.)

          If view is specified (the default case), the attribute names
          specified (see aname below) are first interpreted as display
          window-specific attributes. If a name match is not found in the
          display window-specific list, the global symbol list is then
          searched. If any match is found, the value is returned as a quoted
          string (quotes are only used if the value has embedded spaces or
          quotes). In this view mode, the value is ONLY sent to a specified
          output file or returned to the calling program (such as
          send_xwaves). In this mode, output is NOT sent to xwaves' standard
          output.
     file
          the file name of a specific display window for which attribute
          values are to be obtained. If file is omitted, the most recently
          created display window is assumed.
     output
          the name of an output file to receive keyword-value pairs (in a
          format suitable for a .wave_pro file), in the case where global is
          specified for attributes, or an unadorned list of space-separated
          values if attributes is view or is not specified. If an output
          file is not specified, and attributes is view, then only the
          requesting client (e.g. the send_xwaves program or a program using
          SendXwavesReply() (3-ESPS)) will receive the value(s). The output
          name can include UNIX environment variables (for example $HOME).
     aname
          a quoted string list of the name(s) of the symbols whose values
          are to be retrieved. If aname is omitted in the attributes view
          mode, nothing is returned. If omitted in the attributes global
          mode, all currently defined global symbols are returned as
          keyword-value pairs. The value(s) of the aname item may be any of
          the symbol names listed in chapter 27 and any new symbols you may
          have defined.

     The primary utility of get as an object command is to permit other
     programs to retrieve display window-specific information from xwaves
     via the send_xwaves  program. For example, suppose a program called
     from a UNIX script wanted to know the exact segment of a signal on
     display in xwaves. Assuming the program name was foobar, a command like
     the following might be used:

          foobar `send_xwaves dat get file dat.sd aname \
             view_start_time view_end_time`


     where dat is the display object name and dat.sd

     is the display window of interest. foobar would then get two
     command-line arguments, namely the time, in seconds, corresponding to
     the left and right edges of the display window on dat.sd.

     Another example (use with caution!) could be used to eliminate any
     files that have been created by xwaves operations:

          rm -f `send_xwaves get aname new_files`


insert
     INSERT FILE INTO SIGNAL IN WINDOW

     file
          The name of the signal in which something is to be inserted. This
          attribute is mandatory.
     source
          The name of any existing (but not necessarily displayed) file that
          is to be inserted. This attribute is mandatory.
     time
          The time in file at which source is to be inserted. This attribute
          is mandatory.
     output
          The name of the resulting output file. This attribute is optional.
          If output is omitted, the current outputname will be used (as
          entered in the OUTPUT file: control panel item) or or a filename
          will be constructed (see the section ``The Main Control Panel'' of
          the full manual at the description of OUTPUT file:). Output may be
          the same as file.

mark
     APPLY TIME MARKS TO ALL DISPLAY WINDOWS IN THE OBJECT

     time
          time point (sec) at which to apply the mark.
     color
          colormap entry number (0-127); sets marker color. If omitted, the
          default color that is assigned to markers is assumed (see the
          table ``Meaning of the high-numbered color values'' in the full
          manual).

     Historically, these marks were only used in conjunction with the
     attachments. As of waves+ version 5.0, you may access these mark
     locations directly with xwaves. For example, suppose you wanted to
     cause the keyboard space-bar to play the segment between the two marks
     on either side of the current cursor position. These marks might have
     been applied by any means, including by the programs xlabel or xmarks.
     The following two commands would set up the mapping:

          add_op name play_m op # _name play start \
             _l_mark_time  end _r_mark_time
          key_map key _ op play_m


     Note that this is something different than play between marks! In this
     example it is assumed that mark_reference is cursor_time. See the entry
     for mark_reference in chapter 27.3

marker
     MOVE THE RIGHT OR LEFT TIME MARKER

     time
          the desired time location of the marker (sec).
     do_left
          logical (0 or 1) determines if right or left mark.

     See also the display window set command and the l_marker_time  and
     r_marker_time  object symbols.

op
     CALL ANY OPERATOR AS AN OBJECT COMMAND

     file
          the name of the file whose display window is to be manipulated.
          This is the name used in the make command or other specification
          that created the display window. If omitted, the most recently
          created display window is assumed.
     c_chan
          the channel over which you wish to simulate the cursor location.
          This optional specification is only relevant if the operation to
          be performed needs the channel information (e.g. to select a
          particular vector element from a vector signal). If omitted, the
          channel last accessed (e.g. via mouse pointer movement) will be
          used.
     c_yval
          the simulated value of the cursor in ordinal data coordinates.
          Thus, if the vertical limits of a data display window were -10000
          to 10000, a c_yval of 5000 would simulate a cursor position 1/4 of
          the display window height from the top. If omitted, the last
          actual cursor position is assumed.
     c_time
          the simulated time (in seconds) at which the cursor is located. If
          omitted, the current cursor location will be used.
     op
          a quoted string containing the exact name of the operator to be
          invoked. This is the name specified when the operator was created
          with the add_op or add_waves command, or the exact name appearing
          in one of the xwaves data display window menus. In this context
          command is an exact synonym for op if you find the latter
          confusing. NOTE: the op command does not discriminate among the
          menu-operator lists. It uses the first operator it finds while
          scanning ALL operator lists. It starts with the wave list, then
          the spect list, then other lists in the order in which you created
          them.

     The op command is designed as a convenience for instances when it is
     desirable to simulate some display window-oriented operation. The
     operators that are accessed via op are usually designed to be invoked
     from display window menus or keyboard bindings (see the add_op and
     key_map commands in section 26.2). As such, these operators are called
     as methods of the display window in question. op permits simulation of
     this behavior.

     For example, suppose you designed an operator that echoed the value of
     the spectral amplitude under the cursor in a spectrogram display window
     with an add_op command like this:

          add_op name S-value menu spect op \
             echo _cursor_value


     This operator will appear in the spectrogram display window menu and,
     when selected, will cause the data value under the cursor to be printed
     out. Now, an external program can access this operator to get the data
     value corresponding to 1000Hz and .5 seconds in the data object named
     dt and file named dt.hp.fspec

     with the command:

          send_xwaves dt op file dt.hp.fspec c_yval 1000 \
             c_time .5 op S-value


     N.B.: All calls to the built-in menu items can be made in this way.

open
     OPEN A DATA DISPLAY WINDOW THAT IS CLOSED (ICONIZED)

     file
          full name of the ``iconized'' signal to be opened. Performs the
          same operation as the window system's open or restore.

overlay
     OVERLAY A SIGNAL ON AN EXISTING DISPLAY WINDOW

     file
          the filename of the overlay data. This can be any ESPS FEA file
          except a FEA_SPEC file. NIST  Sphere-format files or AT&T SIGnal
          files are also acceptable. The overlay does not need to be the
          same data type or sample rate as the file to be overlaid. It's
          always handy if there is some meaningful relation between the
          overlay and its host display window, but this is not enforced. The
          time interval that is common to both the host and its overlays
          will be the region overlaid. (i.e. the start times and durations
          of the signals are observed correctly).
     on_file
          the name of the display to be overlaid. This is the name of any
          existing xwaves data display window of any type. If omitted the
          overlay will be put on the most recently created spectrogram, if
          one exists, else the most recently created display window of any
          kind.

     On color systems, overlays are plotted in colors distinct from the host
     display window. Colors of overlays start at entry number 117 in the
     colormap table. This entry is labeled "YA2" in the system colormap
     table in $ESPS_BASE/lib/waves/colormaps/COLOR_MAP. You can make a copy
     of this and modify it to your liking. See the section ``Colormaps'' of
     the full manual and xcmap    for more details. Successive overlays on
     the same display window use successive table entries.

     Multiple overlays on the same host display window are performed by
     issuing multiple overlay commands. Overlays may be removed from display
     windows with the kill command. Note however, the kill command will
     remove all displays of a given file name from the named display object.
     So if it is necessary to distinguish between a host view and an
     overlay, they should have different names.

page
     PAGE SIGNAL IN WINDOW

     file
          the name of the signal to be paged forward or back. If omitted,
          the name from INPUT file: in the command window is used.
     step
          If positive, the number of seconds to page forward; if negative,
          the number of seconds to page backwards. If omitted, the value of
          the global ref_step  is used.
     ref_step
          optional new value for the global ref_step.

play
     D/A CONVERT DATA IN A SAMPLED-DATA DISPLAY WINDOW

     file
          data display window name to be played. If omitted a ``playable''
          file is sought by xwaves using various heuristics. This search
          includes backtracking through the header of the loaded signals for
          the source data from which it was computed. This often works
          correctly! So, if you ask to play a spectrogram, you will usually
          hear the file from which it was generated.
     start
          starting time (sec) for D/A conversion.
     end
          end time.

     If times are omitted, file limits are used.

play_wind
     PLAY WINDOW

     file
          the data shown in the displayed window for this file are played.
          If file is not given, some heuristics are used to find a window to
          play.

print_ensemble
     PRINT GRAPHICS IN WINDOWS OF OBJECT

     The graphic images in the display windows of the object are rendered in
     PostScript. Attachment windows may be included. The output is either
     saved in a file or sent to a UNIX command. The actions of this command
     are controlled by a set of globals. See the chapter ``Printing
     Graphics'' of the full manual.

print_graphic
     PRINT GRAPHIC IN WINDOW

     file
          the full name of the signal in the display window to be printed.
          If the signal is displayed in more than one window of the object,
          one window is chosen.

     The graphics image in this window is rendered in either PostScript or
     PCL. It is either saved into a file or sent to a UNIX command. The
     actions of this command are controlled by a set of globals. See the
     chapter ``Printing Graphics'' of the full manual.

save
     SAVE SEGMENT IN OUTPUT FILE

     file
          the name of the signal file containing the segment to be saved.
          The name of the file into which the segment is saved is determined
          by the OUTPUT file:  item in the xwaves control panel (see
          description of the OUTPUT file: item in the section ``The Main
          Control Panel'' of the full manual).
     outputname
          the name for the output file. This changes the global value of
          outputname and the saved segment uses this new specification. See
          section 27.2 for more details.
     start
          the start time of the segment to be saved.
     end
          the end time of the segment to be saved.

     Note that, by default, xwaves applies certain file name extensions
     following the name specified by outputname, depending on the type of
     data in the file. You may disable this behavior by setting the global
     apply_extensions  to zero.

set
     SET THE VALUE OF ONE OR MORE DISPLAY WINDOW ATTRIBUTES (OBJECT SYMBOLS)

     <any display window attribute name>
          See section 27.3 for a complete listing of the built-in symbols.
     file
          the name of the file in the display window whose attributes are to
          be varied. This is the same name used in the creation of the file
          with the make command or entered in the INPUT file: item of the
          main control panel. The name of the file MUST precede the
          attributes that are to be varied. If attributes for more than one
          file are to be set with a single set command, multiple file
          specifications and attribute lists may be interleaved.
     channels
          A simple quoted string containing a space-separated list of
          channels to be accessed. These channels correspond to the vector
          element numbers in the signal, starting with channel 0. If the
          channels specification is absent, all channels in the display
          window will be affected. If different attributes are to be varied
          over different channels in the same set command, any number of
          channels and attribute specifications may be interleaved.

     The object set command permits individual attribute settings in any
     xwaves display window, either by external programs, via the send_xwaves
     facility, or internally, via add_op operator definitions. A simple
     example that turns the reticle off in display window speech.sd of
     display object speech might look like this:

          speech set file speech.sd reticle_on 0


     Or, suppose you wanted to create an operator bound to the left mouse
     button that changed the waveform color of any element trace to colormap
     entry 117. These two commands would do the trick:

          add_op name HILIGHT menu wave op # _name set \
             file _file channels _cursor_channel \
             line_color 117
          set left_op HILIGHT


     The next waveform display window(s) you created would have this
     feature.

     If you wanted an existing waveform display window to immediately assume
     the new left mouse button definition, the second command above could be
     changed to:

          speech set file speech.sd left_op HILIGHT


     where speech and speech.sd are the object and display window names,
     respectively. This would cause ONLY that display window to assume the
     new characteristic. If you wanted all current and subsequently created
     display windows to have the feature:

          set all t left_op HILIGHT


     Note that in the first and third example of mouse button binding, we
     used the global set command, to set the variable, rather than the
     object set command. Full syntax for these would have been:

          waves set left_op HILIGHT


     and

          waves set all t left_op HILIGHT


spectrogram
     MAKE A SPECTROGRAM OF DISPLAYED SAMPLED DATA

     file
          name of sampled data display window. If omitted xwaves looks for
          first file with a .sd or .d extension. Failing this, it tries to
          find a reasonable file from which to compute a spectrogram.
     loc_x
          x coord. of upper left corner for spectrogram window.
     loc_y
          y coord. of upper left corner for spectrogram window.
     type
          allowed arguments are wideband  and narrowband .
     start
          starting time (sec.) for spectrogram computation.
     end
          end time. If either times are omitted, display window limits are
          used.
     height
          height in pixels of spectrogram display. If v_spect_rescale is
          enabled, the spectrogram will be scaled to fit this size. If not,
          the window may be partly empty or the top of the spectrogram image
          may be truncated. If height is not specified explicitly the window
          will be sized to fit the spectrogram: one pixel per frequency
          point.
     width
          width in pixels of spectrogram display. If h_spect_rescale is
          enabled, the spectrogram will be scaled down, if necessary, to fit
          this size. If horizontal scaling is not enabled, the window may be
          partly empty or the scrollbar may be used to access the off-screen
          parts of the spectrogram. If width is not specified explicitly the
          window will be sized to fit the spectrogram: one pixel per time
          point.
     threshold
          level (dB) below which spectral densities are white. See
          discussion under the colormap command.
     range
          dB from start to end of current colormap (dynamic range).
     image_clip
          an alternate way to specify intensity mapping clipping limits
          (image_clip = 105 - threshold - range).
     image_range
          same as range.
     output
          the name of a file to store the spectrogram data in in cases where
          an external process must be called to compute the spectrogram. If
          output is omitted, .fspec is appended to the input filename and
          possibly an additional number to make the name unique. Files
          generated by the spectrogram command are added to the new_files
          list. See section 27.2.

unmark
     REMOVE TIME MARKS FROM THE OBJECT

     all
          If argument is t or T all marks of any color will be removed.
     time
          remove mark only at the specified time. If omitted and all not
          specified, nothing happens.
     color
          color of the mark at time to be removed. If omitted, the color in
          the color table that is assigned to markers is assumed (see the
          table ``Meaning of the high-numbered color values'' in the full
          manual). If the color of the mark and that specified to the unmark
          do not match, the mark is not removed.

----------------------------------------------------------------------------

Chapter 27

xwaves symbols reference

This section lists and explains all built-in symbols used in xwaves. There
are two major categories of symbols that are used:

global
     The values of these tend to have a global effect on xwaves'
     performance.
object
     These tend to convey or determine the condition of data display windows
     on a window-by-window basis.

----------------------------------------------------------------------------

   27.1  Introduction
   27.2  Global symbols
   27.3  View-specific symbols
         27.3.1  Read-only (get only) object symbols
         27.3.2  Write-only (set only) View Symbols
         27.3.3  Read-Write (get or set) View Symbols
         27.3.4  Notes for display window specific symbols

----------------------------------------------------------------------------

27.1  Introduction

The state of the globals may be accessed by the xwaves (global) commands
get  and set . The initial condition of these may be set by entries in your
startup xwaves profile file (normally $HOME/.wave_pro  if it exists, and
$ESPS_BASE/lib/waves/.wave_pro otherwise). Both global and the gettable
object symbol values may be used in add_op  commands as described under
add_op in the section ``Using Symbols in the add_op Command'' of the full
manual and in section 26.2. These are also accessible using the object get
command via the program send_xwaves.

You may create your own global variables just by assigning values to symbols
of your own choosing. Internally, xwaves always stores these as simple
quoted strings, but in other respects they behave exactly like any other
global and may be accessed with get commands and used as variable symbols in
add_op commands. A possibly-confusing side effect of this feature is that no
global set commands will produce error messages if there is a typo in the
symbol name. A new global will simply be created, so be careful!

As of waves+ 5.1 symbols may contain commands as their value and\ can thus
be executed. Look at the description of add_op in section 26.2.

The state of the object symbols may be accessed using the object commands
get and set (see section 26.4). Many object symbols are read-only or
write-only. This distinction will be pointed out below.

In many cases the state of a global symbol is used to initialize an object
symbol when the display window is created. Prior to xwaves version 5.0,
there was no clear distinction between this initialization function and the
operation of changing display window states after the display window was
created. This is now explicitly implemented. For example, prior to xwaves
5.0, setting the global symbol middle_op caused all existing and new display
windows to assume that middle mouse button binding. It is now possible to
specify different a middle_op for each display window, if desired, using the
object set command without affecting the state of either the global symbol
or the bindings in other display windows.

The code in table 27.1 below will be used to indicate the type of the
symbols. This is usually only of concern when their values are being set,
since the values are always encoded as ASCII strings when returned by
xwaves. When xwaves returns items that are strings with embedded spaces or
double quotes, these items are delimited by double quotes. The type key will
precede the description of each settable variable.

  Table 27.1: List of types for the settable symbols
----------------------------------------------------------------------------

D
     double-precision scalar numeric (any numeric format is OK)

I
     32-bit integer numeric (any integer is acceptable)

B
     Boolean (0 is FALSE any non-zero integer is TRUE)

Q
     A quoted string as defined in the GLOSSARY section

SQ
     A simple quoted string as defined in the GLOSSARY section

S
     a string with no embedded spaces or quotes; usually a name

----------------------------------------------------------------------------

Here are a few examples that summarize the access mechanisms available for
the various symbol types. In the following we will assume the existence of a
display object named dis and a data display window in the file dis.sd.

To assign global values:

     waves set play_prog sgplay

or

     set play_prog sgplay

or to set two items

     set middle_op "play between marks" play_prog sgplay

To create new globals:

     set my_sym "my arbitrarily complex value with \
        less than 500 characters"

To set object symbol values:

     dis set file dis.sd reticle_on 0 line_color 117

or if only channels (vector elements) 0 and 3 are to be set

     dis set file dis.sd channels "0 3" reticle_on 0 \
        line_color 117

To access gettables in add_op commands:

     add_op name "what channel?" op echo _cursor_channel

(Note the underline character preceding cursor_channel.)

----------------------------------------------------------------------------

27.2  Global symbols

We start out with the global symbols. The following items may all be
initialized in your xwaves profile file. Some of them ONLY affect the state
of xwaves at startup time.

The value of global symbols marked with a (+) is used to initialize the
corresponding display window-specific value when a new display window is
created. After a display window is created, setting this global will only
effect the display window if the all switch is set in the global set
command. See set in section 26.2.

append_extensions
     B

     When enabled, the save  command and the save segment in file  menu
     operator will append extensions to the saved file's name that are
     related to the file type. Else, the extensions are not appended.

attachments
     Q

     A list of items to appear as pushbutton alternatives for the Attach:
     main control panel item (see also the section ``The Main Control
     Panel'' of the full manual). Startup only.

blowup_op
     Q

     The operator to be invoked after the menu item blow up; function  is
     executed. Attachments typically bind their own mark operation to
     blowup_op , but you can bind any existing operator to it. (+)

colormap
     S

     File name of an RGB color map (see the section ``Colormaps'' of the
     full manual). The default search path for colormap file names is

          .:$ESPS_BASE/lib/waves/colormaps


     To use a different path, set the UNIX environment variable
     WAVES_COLORMAP_PATH  before starting xwaves.

command_step
     B

     Allows the user to single-step through command files. When command_step
     is non-zero, xwaves prints each command before executing it and pauses
     after its execution (except for sleep  commands). The next command can
     then be read and executed by mousing CONTINUE  in the xwaves main
     control panel. sleep commands are not affected by command_step. If
     command_step is non-zero and CONTINUE is moused when the next command
     is sleep, xwaves executes the sleep and then goes on directly to
     execute the subsequent command. If that command is not a sleep, xwaves
     will pause after its execution.

     Note that command_step does enable command echoing when used with
     send_xwaves, but does not impose a pause between commands in this case.
     Command stepping does not work correctly if an attachment is active.

commandname
     S

     This can be used to determine the name of the current waves command
     file (if any) that is executing.

cross_level
     D

     The level used to establish the cursor positions when find_crossing is
     set to 1.

ctlwin_iconized
     B

     If this is non-zero, the xwaves control window is iconized on startup.
     Otherwise the control window is displayed on startup. The default for
     ctlwin_iconized is 0. Note the standard xview command line options -Wi
     (iconic) and +Wi (open) can also be used to determined the initial
     iconization state. Also, the position of the icon can be determined by
     the standard xview command line option -WP <x> <y>.

ctlwin_x
     I

     x coordinate of upper left of control window.

ctlwin_y
     I

     y coordinate of upper left of control window.

da_position
     I

     If set, it should be given the sample around which xwaves needs to
     focus its window when D/A output is interrupted with the left mouse
     button. This is the only moment at which xwaves looks at this value.
     The internal D/A software and the ESPS play programs set this value.
     For examples to use it yourself, see the chapter ``Using Audio'' of the
     full manual. If gotten with the get command during playback, it gives
     the value of the sample that is currently played. If you do two gets in
     sequence and this value does not change you may be sure that the xwaves
     has stopped the playback operation.

debug_level
     I

     Values greater 0 causes debug messages to be printed. The default value
     is 0.

def_header
     S

     Filename of a header for use with headerless data. The default startup
     profile, $ESPS_BASE/lib/waves/.wave_pro, initializes this to
     $ESPS_BASE/lib/waves/files/def_head.feasd, which is an ESPS FEA_SD
     header for single-channel, SHORT, sampled-data, with sampling rate 8000
     Hz. A default SIGnal header is in
     $ESPS_BASE/lib/waves/files/def_head.sig. The default search path used
     for default header file names is

          .:$ESPS_BASE/lib/waves/files


     This path can be overridden by setting the UNIX environment variable
     WAVES_INPUT_PATH  before starting xwaves. If the environment variable
     DEF_HEADER  is defined when xwaves starts up, its value takes
     precedence over def_header. Thus, if you want def_header to change for
     different input files while xwaves is running, then DEF_HEADER should
     not be defined.

     Note that def_header can be included in the attribute list of the waves
     make command. As soon as the variable is set all processes under xwaves
     have the environment variable DEF_HEADER set to the value of
     def_header.

do_color
     B

     0 or 1 to enable B&W or color operation. This global is set
     automatically on startup prior to reading the startup profile, so you
     should set it in the profile only if you don't want the automatic
     setting. Setting it to zero on a color machine will force monochrome
     display windows and dithered spectrograms. Setting it non-zero on
     monochrome systems will usually cause core dumps.

dont_save_sgrams
     B

     This disables the saving of spectrogram data files on most contexts
     where signal files would normally be saved. If you really need to do
     operations like save segment in file  on spectrograms, be sure this
     boolean is 0.

edit_ganged
     B

     1 to simultaneously edit all signals in object, 0 for just one. This
     concerns deletions of segment from files and saving segments.

ens_print_atts
     Q

     A list of attachments to which xwaves will send requests for graphics
     when executing a print_ensemble command (or print ensemble menu
     operation). The items are separated by blanks--for example ``xlabel
     xchart''. The attachments on the list need not actually be attached
     when print_ensemble is run; however, any that are attached will receive
     a request for graphics and must respond as described in the
     section``The Print Command'' of the full manual. At present the
     attachments that are able to respond properly are xspectrum, xlabel and
     xchart.

fea_sd_special
     B

     1 to treat ESPS FEA_SD files as a special case, 0 to treat in standard
     FEA manner. If fea_sd_special == 1, the sampled data from ESPS FEA_SD
     files are read in as SHORTs (regardless of their external
     representation) so that the DSP board can be used for spectrograms. In
     this case, values outside of the range (-32768, +32767) are clipped to
     the extremes of the range. If fea_sd_special == 0, no such conversions
     are performed and the external program sgram_prog  will be used for
     spectrograms. fea_sd_special is set on startup to 1 or 0 depending
     respectively on whether or not the DSP board (or native system DSP
     hardware) is present. OBSOLETE ON MOST SYSTEMS

find_crossing
     B

     When find_crossing is enabled, the cursor will only move to points on
     the waveform that are just over the cross_level. That is, on the first
     sample above the cross_level on the positive slope of the waveform. Of
     course, this means that when the mode is on, the markers can only be
     positioned on these positive level crossings, making it possible to
     very quickly cut out signals that should splice together with minimal
     clicks.

     Note that there is some peril in setting this symbol, since it is
     possible to set the level out of the range of any actual data values.
     This causes xwaves to hunt over the whole view for a crossing. If one
     is not found, the cursor does not move, but the computation does eat a
     lot of CPU cycles! Default is 0.

first_x
     I

     x coordinate of upper left of first data window created. This is then
     automatically incremented by x_increment  with each subsequent display
     window created.

first_y
     I

     y coordinate of upper left of first data window created. This is then
     automatically incremented by y_increment  with each subsequent display
     window created.

funcname
     S

     An attached function (like xlabel or xspectrum). On startup this causes
     the indicated function to be attached automatically. After startup, it
     reflects the most-recently started attachment.

f0_min
     D

     Minimum frequency to display for F0 files. (+)

f0_plot_specs
     Q

     Plotting method and optional ASCII symbol to use. Argument syntax is: N
     s xd yd, where N is 0 or 1, s is the plotting character to use (if N is
     1), xd and yd are the x and y displacements (in pixels) required to
     center the character. If N is 0, F0 is plotted using the usual
     connect-the-dots paradigm. f0_plot_specs must be the last variable set
     on a command line. Currently only the N option is in function. It
     toggles between line and box plot. The other options have no effect.

f0_range
     D

     Range in Hz to display for F0 files. (+)

f0_size
     D

     Fraction of the vertical axis of the F0 display window used for F0
     plotting. 0.0 < f0_size < 1.0.

image_clip
     D

     This determines the limiting levels for translating spectrogram/image
     data to display colormap values. When used by the digital halftone
     algorithm it is assumed that the maximum displayed value, MAX, is 127.
     Values between MAX and (MAX - image_clip) are displayed in black. The
     default value is 7 (i.e., in spectrogram terms, everything above 119dB
     is shown in black). For color/greyscale mappings, the interpretation is
     slightly different (though the effect is qualitatively the same). In
     this case, all data values above (105 - image_clip) are represented by
     the same (high) colormap entry. The available colormap table is then
     interpolated linearly between (105 - image_clip) and (105 - image_clip
     - image_range).

image_range
     D

     This is also used by both the color/greyscale intensity mapper and the
     digital halftone algorithm. Everything below (MAX - image_clip -
     image_range) is shown in white on monochrome displays, or as the lowest
     spectrogram colormap entry on color/greyscale displays. The default is
     40 (i.e., in spectrogram terms, assuming 7 as the value of image_clip,
     everything more than 47db down from the maximum possible value is shown
     in white).

init_file
     S

     The name of a command file to be executed on startup. Execution takes
     place after all the other variable initializations in the profile are
     done, regardless of where in that file the definition of init_file
     occurs. After the profile has been processed, redefining the value of
     init_file has no effect other than changing the output value for the
     command get attributes global . By default, xwaves looks for init_file
     along the path

          .:$ESPS_BASE/lib/waves/commands


     The search path used can be overridden by setting the UNIX environment
     variable WAVES_COMMAND_PATH  before starting xwaves. STARTUP ONLY.

inputname
     S

     Default pathname to appear at INPUT file:  prompt. When accessed as a
     symbol, it returns the name of the most recently created data display
     window. Setting this symbol does nothing by itself.

invert_dither
     B

     If set to non-zero, this causes the display of digital-halftone images
     to appear with black and white pixels reversed ("inverse video").
     Spectrograms are displayed in digital halftone form on all monitors or
     when do_color  is set to 0. (+)

left_op
     Q

     Text corresponding to desired left button operation for new waveform
     windows. This may be the exact name of any xwaves operator, including
     those created with the add_op or add_waves commands. (+)

line_type
     I

     Plotting algorithm to use for plotting generic vector signals. See
     line_type in section 27.3. (+)

max_buff_size
     I

     Determines a limit on the number of bytes of storage that xwaves will
     attempt to allocate for in-memory data storage for any one signal. The
     value is 2,000,000 by default, but of course can be changed via the
     startup profile or a set command. If this limit is set high enough for
     a signal to be contained entirely in memory, operations such as
     scrolling through the signal will be faster than they would be
     otherwise, since xwaves will not have to reread data repeatedly from a
     disk file. Smaller values of the limit may be necessary to prevent
     xwaves from failing by running out of memory.

middle_op
     Q

     Text corresponding to desired middle button operation for new waveform
     windows. This may be the exact name of any xwaves operator, including
     those created with the add_op or add_waves commands. (+)

min_spec_height
     I

     Minimum height in pixels of spectrogram windows. If there are more
     spectral values per record than min_spec_height, the initial window
     size is set at one pixel per spectral value.

min_spec_width
     I

     Minimum width in pixels of spectrogram windows.

nb_spect_params
     S

     File with parameters for narrowband spectrograms (see also
     wb_spect_params). The default filename is nb_params, and the default
     search path used is

          .:$ESPS_BASE/lib/waves/files


     This path can be overridden by setting the UNIX environment variable
     WAVES_INPUT_PATH  before starting xwaves.

objectname
     S

     Default name to appear at OBJECT name:  prompt. When used as a symbol,
     it indicates the most recently created object.

objects

     The value of objects is a space-separated list of all the display
     objects.

output_dir
     S

     The name of a writable directory to be used for all xwaves output files
     specified as a simple basename or files with names generated
     automatically by xwaves. If output_dir is not defined, output files are
     written in the same directory as whatever file they were derived from
     (or in the current working directory if there is no source file). Do
     not define this global unless you want it used and make sure that the
     named directory exists and is writable. If output_dir is defined, all
     output files from xwaves, xspectrum and xlabel will go into this
     directory (including edited files, saved file segments, spectrogram
     output files, outputs from add_op, etc.).

     It is OK to include environment variables in the path. In the case of
     external function calls (spectrogram calls via sgram_prog , D/A calls
     via play_prog , as well as calls produced by add_op, etc.), output_dir
     can be overridden by the value of remote_path  or remote_output_path .
     To ``unset'' output_dir (so that none is used) do:

          set output_dir


outputname
     S

     Default pathname to appear at OUTPUT file:  prompt. This may be reset
     at any time to establish a new output name for save segment in file
     and other editing operations. Setting this symbol does nothing by
     itself.

overlay_as_number
     B

     See overlay_as_number in section 27.3. (+)

overlayname
     S

     Pathname to a file to be overlaid on another data display window. When
     accessed as a symbol, this returns the name of the most recent overlay
     signal. Setting this symbol does nothing by itself.

play_prog
     Q

     The name of the xwaves -external D/A play program to use. This program
     should at least allow for the arguments: -r<start>:<end> <file>, which
     are the standard options with which play_prog is called. The default is
     s16play  on Suns, sgplay  on SGI and hpplay  on HP. play_prog can have
     blanks in it, so it can include the specification of standard options.
     See also the discussion in the chapter ``Using Audio'' of the full
     manual.

     As of waves+ 5.1 D/A may be performed using functions internal to
     xwaves for many workstation types. To enable this, DO NOT define either
     use_dsp32 or play_prog in .wave_pro.

plot_max
     I

plot_min
     I

     See plot_max and plot_min in section 27.3. (+)

print_graphic_command
     S

     If print_graphic_printer == 1 then graphics is sent to stdin of this
     command. This is usually the spool command. Default value is lpr.

print_graphic_file
     S

     The filename to write the graphic output to if the value of
     print_graphic_printer is zero. Default value is waves.prt. Of course,
     this and all the other print specifications can be changed while xwaves
     is running.

print_graphic_printer
     I

     A value of 1 causes the output graphic to be sent to the UNIX command
     in print_graphic_command. A value of zero causes the output graphic to
     be written into the filename in print_graphic_file. The default value
     is 1.

print_graphic_resolution
     I

     The resolution of the output device. The default value is 300.

print_graphic_orientation
     S

     The orientation of the graphic on the ``page'': either LandScape  or
     Portrait . Default value is Portrait.

print_graphic_scale
     Q

     This is a floating value. A value other than 1.0 causes the image to be
     scaled up or down. Since the printer has a higher resolution than the
     display it is often desirable to scale the image up by a factor of 2.5
     to 3.0. The default value is is 1.0.

print_graphic_type
     S

     The format of the image: either PostScript  or PCL . Default value is
     PostScript. The strings are not case sensitive.

print_only_plot
     I

     If 0 then the saved graphic is as shown on screen. If 1 then most
     labels shown on screen do not go out in saved graphic. In particular,
     this inhibits the printing of cursors and markers. The default value is
     0.

print_ps_level
     I

     This specifies the PostScript  language level: either 1 or 2.
     PostScript Level 1 does not support color spectrograms. PostScript
     Level 2 does, but it might not work on all PostScript devices.

readout_bar_height
     I

     Height in pixels of the readout bar, which contains various digital
     readouts. The bar is located below the title bar and above the
     scrollbar. (+)

redraw_on_release
     B

     See redraw_on_release in section 27.3. (+)

ref_size
     D

     Initial size of the display buffer (sec.). Don't make this bigger than
     necessary, because it may cause memory fragmentation for multi-channel
     files. (+)

ref_start
     D

     Initial default starting time for file display (sec.).

ref_step
     D

     Page step size for page ahead/back  (sec.). (+)

remote_input_path
     S

     If remote_input_path is defined, it is prefixed to the basename of all
     input file names in external calls. It overrides any definition of
     remote_path.

remote_output_path
     S

     If remote_output_path is defined, it is prefixed to the basename of all
     output file names in external calls. It overrides any definitions of
     remote_path and output_dir.

remote_path
     S

     If this string is defined (and not overridden by either
     remote_input_path or remote_output_path as described above), it is
     prefixed to the basename of all input and output file names in external
     calls (play operations, spectrogram operations, operations from
     add_op). This is useful for operation in an NFS directory with rsh . If
     remote_path is defined, it overrides output_dir  in the case of
     external calls. See the discussion in the section ``ESPS commands as
     UNIX extensions'' of the full manual.

reticle_grid
     B

     Determines whether (1) or not (0) the reticle is displayed on
     newly-created display windows. See reticle_on  in section 27.3. (+)

rewrite_after_edit
     B

     See rewrite_after_edit in section 27.3. (+)

s_range_offset
     I

     The internal convention in xwaves is to represent samples in a file
     starting the count at 0. Other programs (including most ESPS programs)
     start counting at 1. s_range_offset is a means to adjust this
     discrepancy or to allow you to define built-in offsets for some other
     purpose (perhaps to compensate for a system delay, etc.). This offset
     is added to all ``sample number'' display window-specific variables.
     Its default value is 1. It has no other impact on xwaves operation.

samp_range_prefix
     Q

     The string contained in this variable is prepended to all sample
     ranges, of the form M:N, returned by the display window-specific
     symbols range_samp  and mark_range_samp . By default it is -r which
     meshes well with ESPS programs that have a command-line range option.
     You may specify a null prefix with "".

scrollbar_height
     I

     Height of the scrollbar in new windows (pixels). (+)

scroll_ganged
     B

     1 to scroll all signals in object, 0 for just one (see also
     zoom_ganged ).

sgram_prog
     S

     The name of the external spectrogram program to use. The default is
     sgram . sgram_prog can have blanks in it, so it can include the
     specification of standard options. The default is nil. See the
     discussion in the section ``ESPS commands as UNIX extensions'' of the
     full manual. (See also play_prog.)

shorten_header
     B

     If enabled, this boolean causes the file name displayed in the
     upper-left corner of each data display window to be simplified to its
     base name with any path prefix removed. (+)

show_labels
     B

     1 to display FEA field names at the left of the corresponding parameter
     track in waveform windows, 0 to inhibit the display of names. (+)

show_processes
     B

     If 1 a ``process pending'' indication is displayed in xwaves. The GUI
     appears when any processes started from xwaves are pending. The simple
     display shows the list of PID's of all top-level processes pending.
     Left mousing any list member produces a message panel showing the full
     command line being executed under that PID. The message panel has two
     buttons OK and Kill This Process. OK just dismisses the command
     display. Kill This Process issues two kill() calls, one for the
     top-level PID (the shell that was forked) and one for the presumed
     sub-process. After the kill, the internal state of xwaves is
     reconfigured appropriately to clear up any pending actions that would
     have occurred on normal process completion. Default value is 1.

show_vals
     B

     1 to display numerical values at the left lower corner of every
     parameter track in waveform windows, 0 to inhibit the display of
     values. The values displayed are the parameter values at the cursor,
     and they change dynamically as the cursor is moved. If there are a
     large number of FEA fields being displayed, the constant update of the
     parameter values can be time consuming. (+)

sig_max_override
     D

     Maximum to be assumed for all internal D/A  operations. xwaves
     amplifies this value to the maximum level of the D/A device. Large
     numbers cause more scaling down, small numbers cause less scaling down.
     0 means autoscale.

socket_port
     I

     This is the INET domain socket port number to be used when xwaves is
     operating as a display server (as the result of the -s option or the
     enable_server  command). If set, socket_port overrides the WAVES_PORT
     environment variable or the value given by the -p option. Note that
     this port number is no longer relevant for the send_xwaves  program. It
     is, however, still used when communicating with the send_xwaves library
     calls and with the program plot3D . This inconsistency will be removed
     in a future release.

spec_left_op
     Q

     Text corresponding to desired left button operation for new spectrogram
     windows. This may be the exact name of any xwaves operator, including
     those created with the add_op or add_waves commands. (+)

spec_middle_op
     Q

     Text corresponding to desired middle button operation for new
     spectrogram windows. This may be the exact name of any xwaves operator,
     including those created with the add_op or add_waves commands. (+)

spect_interp
     B

     1 to cause linear interpolation in rescaled spectrogram displays; 0 to
     disable interpolation so that each discrete value is shown as a uniform
     rectangle. If data are interpolated then the range of the interpolated
     data computed together is determined by spect_rescale_scope . (+)

h_spect_rescale
     B

     1 to cause horizontal rescaling of spectrogram displays; 0 to cause
     fixed displays with 1-pixel per data record. See h_rescale  in the
     ``View-Specific Symbols'' section. (+)

v_spect_rescale
     B

     1 to cause vertical rescaling of spectrogram displays; 0 to cause fixed
     displays with 1-pixel per data record. See v_rescale  in section 27.3.
     (+)

spect_rescale_scope
     S

     Determines whether horizontal rescaling of interpolated data is
     computed for the entire xwaves buffer (value is buffer ) or for just
     the current window width (value is view ). Rescaling for the entire
     buffer can be quite slow if the ratio of the current display window to
     the entire buffer is large, but has the advantage that horizontal
     scrolling is very fast once the new image is computed (since it is
     stored). Rescaling just the current display window is faster (and is
     the default), but has the disadvantage that the rescaling takes place
     every time the viewpoint is moved (i.e., scrolling is slower). In later
     releases, this global will also affect the rescaling of
     non-interpolated data. See rescale_scope  in section 27.3. (+)

temp_path
     S

     Determines the directory in which xwaves will write temporary files
     (e.g., files generated by external ESPS calls that result from xwaves
     command add_op). The default for temp_path is ``.'' (i.e., current
     working directory).

time_range_prefix
     Q

     The string contained in this variable is prepended to all time ranges,
     of the form A:B, returned by the display window-specific symbols
     range_time  and mark_range_time . By default it is -s. You may specify
     any prefix, including a null prefix with "".

use_dsp32
     B

     1 to use dsp board, 0 to ignore dsp board. This is normally set by
     xwaves on startup depending on whether or not certain boards are
     detected. On most machines use_dsp32 really means ``use compiled-in D/A
     routines rather than external programs''. In that case, if use_dsp32 is
     zero, all D/A will happen using an external play program, which is
     probably a bad idea unless you have a good reason to do it. On all
     machines, the ``right thing'' usually happens if you DO NOT define
     use_dsp32 in your profile file,

verbose
     I

     Values > 0 cause various feedback messages to be printed. When verbose
     > 0, xwaves prints a startup message indicating the identity of the
     .wave_pro file that was read and it prints copies of the shell command
     lines used to invoke external ESPS functions as well as all shell
     commands that result from calling the xwaves command shell. When the
     shell commands have completed, a completion message is printed.
     Unrecognized xwaves commands are reported as such (for verbose > 0).
     When verbose > 1, xwaves prints detailed feedback about command
     parsing. The default value of verbose is 1.

wave_height
     I

     Height of new waveform windows (pixels). (+)

wave_width
     I

     Width of new waveform windows (pixels). (+)

wb_spect_params
     S

     File with parameters for wideband spectrograms (see also
     nb_spect_params). The default filename is wb_params, and the default
     search path used is

          .:$ESPS_BASE/lib/waves/files


     This path can be overridden by setting the UNIX environment variable
     WAVES_INPUT_PATH  before starting xwaves.

write_common
     B

     If write_common is 1, each time the mouse is used to change the
     position of segment markers, the file name (``filename''), starting
     record (``start''), and number of records (``nan'') are written to the
     ESPS Common file; if write_common is 0, Common is not written. For more
     information about ESPS Common processing, see various ESPS manual pages
     (e.g., getparam (1-ESPS) and read_params (3-ESPS)). We DO NOT recommend
     using common for anything. It is an ``evolutionary artifact''.

x_increment
     I

     Horizontal displacement between successive windows (pixels).

y_increment
     I

     Vertical displacement between successive windows (pixels).

zoom_ratio
     D

     Fractional change caused by zoom operations. (+)

zoom_ganged
     B

     1 to zoom all signals in object, 0 for just one (see also
     scroll_ganged).

P8574_type
     B

     1 (default) means correct P8574 version part is on the Ariel analog
     module for the AT&T Surf-board. If you get a message like:

          iicack: bus error, sta=0x8, flag=0x0


     when trying to do analog output, then you might have an Ariel board
     with the wrong version P8574P on it. Some have been shipped with the A
     version, which has different addresses. If you get this message, then
     set this global to 0. OBSOLETE

ARIEL_16
     B

     This global is used to tell xwaves that the Ariel analog module (for
     the AT&T or Heurikon Surfboard) has a 16 Mhz crystal, rather than the
     standard 24 Mhz. A value of 0 indicates the 24 Mhz crystal and a value
     of 1 indicates the 16 Mhz crystal. OBSOLETE

ARIEL_HK
     B

     This is only relevant for Sun VME systems with a Heurikon board and
     Ariel ProPort combination. Enabling this causes the correct microcode
     to be used on that hardware. OBSOLETE

dsp32_wait
     I

     Specifies the number of attempts (at one second intervals) that xwaves
     will make to use an installed DSP board before giving up. The default
     is 5. The purpose of this global is to make the temporary use of the
     board by other programs (v32play, v32record, dspsgram ) less intrusive
     to the xwaves user. OBSOLETE.

----------------------------------------------------------------------------

27.3  View-specific symbols

The display window-specific symbols are broken up into three groups:

  1. Those that are only ``settable''.
  2. Those that are only ``gettable''.
  3. Those that are both settable and gettable.

Note that when any display window-specific attribute is set, the display
window will be redrawn. If the need arises as xwaves evolves, there may be
considerably more parity between the gettables and settables in future
versions.

See section 27.3.4 for the notes on symbols marked with (1)-(7).

----------------------------------------------------------------------------

   27.3.1  Read-only (get only) object symbols
   27.3.2  Write-only (set only) View Symbols
   27.3.3  Read-Write (get or set) View Symbols
   27.3.4  Notes for display window specific symbols

----------------------------------------------------------------------------

27.3.1  Read-only (get only) object symbols

cursor_channels

     The numbers of the channels (vector elements) delimited by the top and
     bottom (horizontal) markers. Numbering starts at 0. (1)

cursor_label

     Contains the field label of the channel closest to the mouse cursor.

cursor_samp

     The sample number (record number) corresponding to the current time
     cursor position. (2)

cursor_value

     The numerical value of the datum which is ``closest'' to the cursor
     position as viewed on the screen.

cursor_values

     The value of all vector elements in the signal at the time
     corresponding to the cursor position. (3)

dur_samp

     Duration in samples of the interval between the left and right markers.
     Corresponds to range_samp.

dur_seconds

     Same as dur_time.

dur_time

     Duration in seconds of the interval between the left and right markers.
     Corresponds to range_time.

files

     All files that are currently members of the object in which the
     selected display window resides.

height

     The display height, in pixels, of the display window.

is_iconized

     This value is 0 if the display window is closed; 1 if it is open.

l_mark_samp

     The sample number corresponding to the mark closest to the left of the
     mark_reference position. (2)

l_mark_time

     The time corresponding to the mark closest to the left of the
     mark_reference position.

l_marker_samp

     The sample number corresponding to the left marker position. (2)

l_marker_samp_from_start

     The sample number corresponding to the left marker position. This
     symbol assumes that record counting starts at zero. This differs from
     l_marker_samp in that that symbol returns the record number incremented
     by s_range_offset. lmsfs is an alias for this symbol.

lmsfs

     Alias for l_marker_samp_from_start.

loc_x

     The x pixel coordinate of the upper-left corner of the display window.

loc_y

     The y pixel coordinate of the upper-left corner of the display window.

mark_range_samp

     The sample range delimited by the marks closest to the left and right
     of the current mark_reference position. (4)

mark_range_time

     The time range delimited by the marks closest to the left and right of
     the current mark_reference position. (5)

name

     The name of the object of which the display window is a member.

new_files

     All new files created in the current run of xwaves, regardless of their
     object membership or current display status. This includes files
     created as the result of save segment in file , files created by
     spectrogram commands, and files created as out. items in add_op
     commands. A useful UNIX command while xwaves is running is rm -f
     `send_xwaves get aname new_files | grep '.fspec'`. It removes all the
     new spectrogram files created by xwaves.

object_commands

     A list of all commands that may be directed at a display object. These
     are explained in section 26.4.

objects

     The value of objects is a space-separated list of all the display
     objects.

operators

     A list of all operators currently available. This is a compendium of
     all operator types and does not distinguish between display window
     types for which they are relevant, or what menu-operator list they are
     on.

overlays

     A list of file names of all signals that are overlaid on the current
     display window.

r_mark_samp

     The sample number corresponding to the mark closest to the right of the
     mark_reference position. (2)

r_mark_time

     The time, in seconds, corresponding to the mark closest to the right of
     the mark_reference position.

r_marker_samp

     The sample number corresponding to the right marker position. (2)

range_chan

     The vector element numbers corresponding to the positions of the top
     and bottom markers. These are presented as M:N, where M and N
     correspond to the bottom and top markers, respectively. (1)

range_samp

     The sample range delimited by the left and right markers. (4)

range_time

     The time range delimited by the left and right markers. (5)

range_yval

     The range in ordinal data space delimited by the top and bottom
     markers. The value is returned as A:B, where A is the value
     corresponding to the position of the bottom horizontal marker and B
     corresponds to the top marker position. Note, that if the top and
     bottom markers are ``closest'' to different vector elements, the values
     returned will be in the domain of the respective elements. (7)

sec/cm

     This is the ``seconds per centimeter'' time scaling used to plot the
     display window. It is a misnomer, since the computation assumes a
     certain number of pixels/cm (32.582), which will be the wrong constant
     for most display devices in the universe! This deficiency will be fixed
     in a future version.

settables

     This is the list of all display window-specific symbols that may be set
     with the set object command.

val/cm

     This is the ``data value per centimeter'' vertical scaling used to plot
     the display window. It is independently determined for each vector
     element in a multi-dimensional signal. It is a misnomer, since the
     computation assumes a certain number of pixels/cm (32.582), which will
     be the wrong constant for most display devices in the universe! This
     deficiency will be fixed in a future version.

variables

     This is a list of all display window-specific variables. It does not
     include the global symbols or the set-only object symbols.

view_channels

     The channels (vector) elements that are actually on display. These
     correspond to the channels that may have been selected with the
     activate  object command. (1)

view_end_time

     The time in seconds corresponding to the right edge of the display
     window.

view_end_yval

     For a spectrogram view, the upper ordinate (frequency) limit of the
     view. For a waveform view, the maximum ordinate value. (Not generally
     useful for multichannel waveform views, where it is the maximum
     ordinate value over all channels.)

view_start_time

     The time in seconds corresponding to the left edge of the display
     window.

view_start_yval

     For a spectrogram view, lower ordinate (frequency) limit of the view.
     For a waveform view, the minimum ordinate value. (Not generally useful
     for multichannel waveform views, where it is the minimum ordinate value
     over all channels.)

waves_commands

     A list of all commands described in chapter 26.

width

     The display width, in pixels, of the data display window.

----------------------------------------------------------------------------

27.3.2  Write-only (set only) View Symbols

See table 27.1 for an explanation of the type indicators for each symbol.

See section 27.3.4 for the notes on symbols marked with (1)-(7).

background
     I

     The color to use as the display window background.

channels
     SQ

     The space-separated list of channel numbers to be affected by any
     subsequent channel-specific attributes (e.g. line_color, line_type,
     reticle_on, ...). Multiple channel specifications are permitted in a
     single set command.

edit_ganged
     B

     Not currently implemented as a display window-specific item (currently
     has no effect).

h_rescale
     B

     Determines whether the time base should stretch and shrink so that the
     duration of the signal shown in the display window remains constant
     regardless of display window width. (Currently this is fully
     implemented only for spectrogram views.)

invert_dither
     B

     For black-and-white spectrograms, this determines whether the plot is
     white on black or black on white.

left_op
     Q

     The menu operator to be invoked when the left mouse button is pressed
     in the data display window. This can be any of the built-in operations
     shipped with xwaves or any new operators you have defined for the
     display window type using the add_op command. The operator must have
     been defined before the left_op assignment is made.

line_color
     I

     The color of the line to be used when plotting the data for the
     specified channels. (6)

line_type
     I

     A code number in the range 1-4 that indicates the style of plotting in
     waveform display windows. The currently-available styles are:
     1
          connect the data points with straight-line segments.
     2
          same as 1, but draw a vertical line from the data point to the
          minimum value plotted in the specific channel.
     3
          ``DSP style'' This draws vertical lines from the data point to the
          zero line.
     4
          same as 3 and 1 combined.

middle_op
     Q

     The menu operator to be invoked when the middle mouse button is pressed
     in the data display window. This can be any of the built in operations
     shipped with xwaves or any new operators you have defined for the
     display window type using the add_op command. The operator must have
     been defined before the middle_op assignment is made.

move_op
     Q

     The menu operator to be invoked when the cursor is moved in a waveform
     or spectrogram display window. The operator is invoked for every pixel
     that the cursor moves. It could for instance be bound to a call to
     xspectrum, which would result in the calculation of a new spectrum for
     each pixel that the mouse cursor moves. Processor speech will however
     mostly limit the use of this command.

     This can be any of the built-in operations shipped with xwaves or any
     new operators you have defined for the display window type using the
     add_op command. The operator must have been defined before the move_op
     assignment is made.

overlay_as_number
     B

     When vector signals are overlaid on spectrograms (e.g. ``formant
     trajectories''), the overlay positions can be indicated as numerals,
     rather than as colored dots. Enabling this boolean causes numbers to be
     used. This can be helpful when preparing monochrome hardcopy or when
     working on monochrome monitors.

page_step
     D

     The number of seconds to advance the view into the signal file with
     each invocation of the page ahead  or page back  menu items.

plot_max
     D

plot_min
     D

     These are the maximum and minimum values to be represented in the
     specified display window channel(s). Setting these such that plot_max
     is strictly greater than plot_min will automatically cause the
     specified channels to disable v_rescale. I.e., the channels will be
     plotted with the vertical limits specified regardless of the data
     values. If plot_min is greater than or equal to plot_max, auto
     rescaling will resume.

readout_bar_height
     I

     The space, in pixels, between the top of the data plotting area and the
     top of the window. This region contains the scrollbar and several
     numeric printouts, depending on the display window type. When in this
     region, the scrollbar operating mode of the mouse is active.

redraw_on_release
     B

     When editing data by ``drawing'' on the display window with a mouse
     button, redraw_on_release causes the display window to be redrawn each
     time the drawing button is released. For some display window types,
     this might be painfully slow, so you may prefer to disable this
     behavior.

rescale_scope
     S

     This applies only to spectrogram display windows. It can have two
     values: buffer  or view . It determines whether horizontal rescaling of
     interpolated data is computed for the entire xwaves buffer (value is
     buffer) or for just the current window width (value is view). Rescaling
     for the entire buffer can be quite slow if the ratio of the current
     display window to the entire buffer is large, but has the advantage
     that horizontal scrolling is very fast once the new image is computed
     (since it is stored). Rescaling just the current display window is
     faster (and is the default), but has the disadvantage that the
     rescaling takes place every time the viewpoint is moved (i.e.,
     scrolling is slower). In later releases, this global will also affect
     the rescaling of non-interpolated data.

reticle_on
     B

     Determines if the specified channel(s) should be plotted with reticles.

rewrite_after_edit
     B

     When editing waveforms by ``drawing'' on the display window with a
     mouse button, this boolean causes the data values to be written to file
     immediately after the drawing button is released. Otherwise the data is
     not written until the display window is destroyed or xwaves exits.

scroll_ganged
     B

     This display window-specific attribute has no effect at the present
     time.

scrollbar_height
     I

     The height, in pixels, of the region bar plotted in the scrollbar
     region.

shorten_header
     B

     If enabled, shorten_header causes the file name displayed in the
     display window frame header to be simplified to its basename. This may
     be convenient if path names are very long or display windows are very
     narrow.

show_labels
     B

     If enabled, this causes the channel identification labels to be plotted
     in the specified channel(s).

show_vals
     B

     If enabled, this causes the data element corresponding to the time
     location of the cursor to be represented numerically in the lower left
     corner of the channel plotting region.

spect_interp
     B

     When there is a many-to-one relationship between the pixel area of a
     spectrogram display window and the underlying data, this boolean
     determines whether the pixel values should be interpolated linearly
     between data points or represented as blocks with constant value
     throughout. The latter plotting mode is considerably slower in many
     cases.

v_rescale
     B

     For waveform display windows, this determines if the specified
     channel(s) should scale so that the maximum and minimum values present
     in the data should be used as the channel display window maximum and
     minimum. It is automatically disabled whenever plot_max  is set greater
     than plot_min . Resetting it will cause the ``auto-rescale'' behavior
     to be reinstated.

     For spectrogram display windows, v_rescale determines whether the
     spectrogram will be scaled in the vertical direction as the display
     window dimensions are changed.

value_offset
     D

     The sole purpose of this variable is to offset the numeric values
     displayed in the xwaves value printout fields. You can find these
     values above the display in spectrograms and in the bottom left corner
     of each channel in vector displays. The y-axes values are not changed.
     Note that all other types of access to the data values will retrieve
     the values as stored in the file. Default value is 0.0.

value_scale
     D

     The sole purpose of this variable is to scale the numeric values
     displayed in the xwaves value printout fields. You can find these
     values above the display in spectrograms and in the bottom left corner
     of each channel in vector displays. The y-axes values are not changed.
     Note that all other types of access to the data values will retrieve
     the values as stored in the file. Default value is 1.0.

zoom_ganged
     B

     This display window-specific variable has no effect at the current
     time.

zoom_ratio
     D

     The time ratio by which the display window will zoom in and out when
     the zoom in  or zoom out  menu items are selected.

----------------------------------------------------------------------------

27.3.3  Read-Write (get or set) View Symbols

See table 27.1 for an explanation of the type indicators for each symbol.

See section 27.3.4 for the notes on symbols marked with (1)-(7).

b_marker_chan
     I

     The channel number over which the the bottom marker exists (or should
     be placed). (1), (7)

b_marker_yval
     D

     The ordinal value in data space corresponding to the bottom marker (or
     where it should be placed). (1), (7)

cursor_channel
     I

     The channel over which the the cursor exists (or where it should be
     placed). (1), (7)

cursor_time
     D

     The time, in seconds, corresponding to the horizontal location of the
     cursor (or the time to which it should be assigned).

cursor_yval
     D

     The ordinal data value corresponding to the vertical location of the
     cursor in the current channel (or where it should be placed). (7)

file
     S

     The filename of the current display window. For set operations, this is
     required to determine to which display window attribute changes should
     be directed. In the context of get commands, the inverse is true. In
     add_op commands, this is the name of the file under the cursor.

mark_reference
     S

     This variable determines the time reference for finding time marks on
     objects. Before waves+ 5.1, it was always assumed that the mark
     variables (l_mark_time, l_mark_samp, r_mark_time, ...) were found in
     relation to the time location of the cursor (i.e. in relation to
     cursor_time). Now, this is determined by mark_reference. It may take on
     the value of any defined global or view-specific symbol name. The value
     that is assigned to mark_reference is the name of a variable (without a
     leading _ !!!). N.B.: it may not be given a value directly!!! Its
     default value is cursor_time. Of course, it can also assume the name of
     user-defined symbols. Thus, one way to get the time locations of the
     marks immediately to the left and right of, say .34 seconds from a
     display object named bob1 would be:

          send_xwaves set mark_reference my_time \
                my_time .34:: \
             bob1 get aname l_mark_time r_mark_time


     Of course, if you don't mind moving the cursor, the same operation
     could be performed without redefining mark_reference, thus:

          send_xwaves bob1 set cursor_time .34:: \
             bob1 get aname l_mark_time r_mark_time


l_marker_time
     D

     The time, in seconds, corresponding to the left marker position (or
     where it should be placed).

r_marker_time
     D

     The time, in seconds, corresponding to the right marker position (or
     where it should be placed).

t_marker_chan
     I

     The channel number over which the the top marker exists (or should be
     placed). (1), (7)

t_marker_yval
     D

     The ordinal value in data space corresponding to the top marker (or
     where it should be placed). (7)

----------------------------------------------------------------------------

27.3.4  Notes for display window specific symbols

(1)
     Each number returned is the sum of the element number and
     c_range_offset  (which is 0 by default).

(2)
     Each number returned is the sum of the sample (record) number and the
     current value of s_range_offset  (which is 1 by default).

(3)
     A space-delimited list of values with no delimiting quotes.

(4)
     The sample range is presented as <samp_range_prefix>M:N where the
     string <samp_range_prefix> is the exact value of the global symbol
     samp_range_prefix . This defaults to -r, but can have any value
     including null. M and N are the starting and ending sample numbers,
     each of which will have s_range_offset added. The default values for
     samp_range_prefix and s_range_offset are compatible with ESPS programs
     that take range arguments.

(5)
     The time range is presented as <time_range_prefix>A:B where the string
     <time_range_prefix> is the exact value of the global symbol
     time_range_prefix . This defaults to -s, but can have any value
     including null. A and B are the starting and ending times in seconds.

(6)
     This is a colormap table entry in the range 0-127. See example
     colormaps in $ESPS_BASE/lib/waves/colormaps and the man page for
     xcmap .

(7)
     Note that there is an interdependence between the channel specification
     and the ordinal data specification. For multi-element vector signals
     (multi-channel signals), the channel number and ordinal value need to
     be interpreted together.

----------------------------------------------------------------------------

Chapter 28

xlabel reference

This chapter contains only a description of commands and symbols for xlabel.
For a full description of file formats and menu items see the chapter
``xlabel'' of the full manual.

----------------------------------------------------------------------------

   28.1  xlabel commands
   28.2  xlabel symbols

----------------------------------------------------------------------------

28.1  xlabel commands

xwaves can be controlled by a command file or by commands from the
send_xwaves facility. Commands from these sources may be passed through to
xlabel via the xwaves send  command (see the chapter``The waves+ Command
Language'' in the full manual and section 26.2).

The syntax of the sending commands is:

     waves send function xlabel op <command for xlabel>

The syntax of the received commands is:

     receiver command [keyword value] [keyword value] ...

The first item, receiver, is either the attachment name xlabel or the name
of a display object. The second item, command, is the actual command name.
Just as for xwaves there is a distinction between global xlabel commands and
object commands. The global commands always specify as receiver the word
xlabel. The other commands specify as receiver the name of the object to
which the label window is attached. This is the name of the xwaves object.
The following commands are recognized by xlabel. We start with the commands
that should be sent to a specific display object:

activate
     SET ACTIVE LABEL DISPLAY FIELDS

     file
          label file whose display is to be changed. If file is omitted, the
          Label File:  from the labeler panel will be used.
     fields
          one or more blank-separated numbers specifying the display fields
          to be enabled. This must be the last attribute on the command
          line.

mark
     INSERT OR REPLACE A LABEL

     color
          index of the colormap entry to be used for the boundary mark of an
          inserted label.
     file
          name of label file to be affected.
     label
          text of a label or one of the special strings *INSERT*, *DEL*,
          etc. (see the section``Label Menus'' of the full manual and the
          key-mapping example in the chapter ``xlabel'' of the full manual.
          The program uses this string instead of putting up the menu and
          getting a selection from the user. This permits full specification
          of a label to be supplied via a send command. If the label string
          is multi-word and is followed by other keyword-value pairs it
          should be enclosed in double quotes. If this keyword is not
          supplied, the labelmenu is popped up.
     replace_field
          number of the field in a multiple-field label to be replaced, when
          the labeler is in replace mode.
     time
          in INSERT mode, the time coordinate at which to insert the label.
          In REPLACE mode, the time relative to which the closest label is
          determined for replacement. This keyword is mandatory.

N.B.: The following commands should be sent to the object xlabel:

kill
     REMOVE ALL OR PART OF A LABEL DISPLAY OBJECT

     name
          name of an existing xlabel display object that is to be partly or
          completely destroyed.
     file
          file name of a particular xlabel display to be destroyed. The
          actual label file is updated to reflect the state of the display
          before the display is removed. If file is omitted, all of object
          name will be removed.

labelfile
     MAKE A NEW OR LOAD AN EXISTING LABEL FILE
     (This is an exact synonym for make.)

labelmenu
     CHANGE TO NEW MENU FILE

     menufile
          same as Label Menu File:  in the control panel.
     name
          name of an existing xlabel display object to which the label menu
          is to be added.
     file
          label file name of a particular xlabel display to which the label
          menu is to be added.

make
     MAKE A NEW OR LOAD AN EXISTING LABEL FILE

     color
          colormap entry to use for the segment boundary marks (new label
          files only). Numbers in the range of 115-125 are best.

     fields or active_fields
          same as fields under activate and Active fields:  in control
          panel.

     labelfile or file
          label file pathname to be displayed or created.

     font
          the font to be used when displaying the labels in the data window.
          Any of the fonts from the listing generated by xlsfonts are
          acceptable. Note that if the font is also specified in the
          labelmenu file, the latter overrides any other font specification.
          Therefore, for maximum flexibility in changing fonts, use label
          menu files without a font specification. Also if you open a
          labelfile that already has a font specified, that specification
          will override this argument to make.

     label_height
          height in pixels of the display area for each label file in the
          display window. Note that this is not settable on a per labelfile
          basis. The setting propagates to all label tiers on display
          window.

     menufile
          UNIX path name of the menu to be associated with the label file
          display. This may bee changed at any time while labeling. Also set
          using Label Menu File:  in control panel. xwaves searches the path
          defined by WAVES_MENU_PATH . The default is

               .:$ESPS_BASE/lib/waves/menus


     name
          Name of the display object to which the label display window is to
          be related.

     separator
          The character used to separate the label fields.

     signal
          a particular signal in the display object. If omitted, the label
          window will always attach to the most recently displayed signal.
          If included, the label window will remain stuck to the specified
          xwaves signal display.

     xlabel_frame_hoff
          See section 28.2.

     xlabel_frame_voff
          See section 28.2.

print
     PRINT GRAPHICS

     This outputs the contents of the label display window as PostScript or
     PCL to a file to line printer. The output attributes may be established
     using the xwaves print setup widget as explained in the xwaves manual
     sections.

quit
     CLOSE ALL LABEL FILES AND EXIT XLABEL

     The alterations to the labels are saved in the file(s) before xlabel is
     stopped.

save_globals
     OUTPUT VALUES OF GLOBAL VARIABLES

     output
          name of a file to receive the values of the global variables.
          Output is a list of keyword-value pairs in a format suitable for a
          .wave_pro. If output is not specified, stdout is used.

set
     SET GLOBALS FOR USE BY LABEL

     <any xlabel variable>
          variables from the list in section 28.2 .

     Initial values for the symbols described below may also be established
     in the startup profile (.wave_pro). For compatibility with previous
     versions of xlabel, some of these variables are accepted without the
     xlabel_ prefix. However, use of the shorter forms in .wave_pro files is
     not recommended, as it is likely to lead to confusion in the long run.
     For the possible variables see the section below.

unload
     CLOSE, UNLOAD AND REMOVE DISPLAY OF A LABEL FILE

     name
          name of display object containing label file.
     file
          name of the label file to be closed.

----------------------------------------------------------------------------

28.2  xlabel symbols

The symbols that are available for xlabel are:

xlabel_ctlwin_x
     I

     Initial x coordinate of upper left corner of the xlabel control window.
     This variable and xlabel_ctlwin_y are accepted by the set command and
     the altered values will be reflected in the output from save_globals.
     However, the control window will not move. Its position is affected
     only by the values at startup time, as read from the startup profile.

xlabel_ctlwin_y
     I

     Initial y coordinate of upper left corner of the control window. See
     the remarks on xlabel_ctlwin_x.

xlabel_fields
     I

     Same as fields under activate and Active fields: in the control panel.

xlabel_font
     S

     Same as font under make. This may be changed dynamically after a label
     file is on display window if and only if a font IS NOT specified in the
     label menu file.

xlabel_frame_hoff

     Vertical offset in pixels when xlabel positions its label panel
     relative to the parent data display. This permits compensation for the
     vagaries of various window managers.

xlabel_frame_voff

     Horizontal offset in pixels when xlabel positions its label panel
     relative to the parent data display. This permits compensation for the
     vagaries of various window managers.

xlabel_insert_mode
     I

     Numeric code with three possible values:
     0
          for REPLACE ;
     1
          for INSERT ;
     2
          for MOVE .

     This makes it possible to initialize the xlabel mode in the .wave_pro

     file or change it via the set command.

xlabel_labelfile
     S

     Same as file under make and Label file: in control panel.

xlabel_label_height
     I

     Same as label_height under make. This height setting propagates to all
     label display windows.

xlabel_menufile
     S

     UNIX path name of the desired menu. This may be changed at any time
     while labeling. Each labelfile in a multiple-label display may have its
     own separate menufile. This may also be set using Label Menu File: in
     the control panel.

xlabel_name
     S

     Same as name under make and Object: in control panel. This is the name
     of a xwaves display object to use for time-synchronizing the labels.

----------------------------------------------------------------------------

Chapter 29

xspectrum reference

This chapter contains a only description of commands and symbols for
xspectrum. For a full description of file formats and menu items see the
chapter ``xspectrum'' of the full manual.

----------------------------------------------------------------------------

   29.1  xspectrum commands
   29.2  xspectrum symbols

----------------------------------------------------------------------------

29.1  xspectrum commands

xwaves can be controlled by manually entered commands, commands in a command
file or by commands from the send_xwaves facility Commands from these
sources may be passed through to xspectrum via the xwaves send command (see
the chapter ``The waves+ Command Language'' of the full manual and section
26.2).

The syntax of the sending commands is:

     waves send function xspectrum op <command for xspectrum>

The syntax of the received commands is:

     receiver command [keyword value] [keyword value] ...

The first item, receiver, is either the attachment name xspectrum or the
name of a display object. The second item, command, is the actual command
name. Just as for xwaves there is a distinction between global xspectrum
commands and object commands. The global commands always specify as receiver
the word xspectrum. The other commands specify as receiver the name of the
object to which the spectrum window is attached. This is the name of the
xwaves object.

N.B.: The following commands are recognized by display objects: i.e., a
display object is the receiver.

kill
     REMOVE XSPECTRUM DISPLAY

     This removes the indicated xspectrum display object and frees all
     resources associated with it.

mark
     COMPUTE A NEW SPECTRUM

     file
          the file name (loaded in xwaves) to be analyzed.
     time
          The center of the analysis window. This causes xspectrum to
          generate a spectrum based on a window centered at time with window
          size given by the current setting of size (sec):  in the control
          panel, if xspectrum is operating in the Cursor +- size/2 Window
          Limits  mode. When operating in the Markers mode, the time
          parameter is ignored.
     rstart
          The start of an analysis window (must be accompanied by a setting
          for rend). Only valid in Markers Window Limits mode of xspectrum.
     rend
          The end of an analysis window (must be accompanied by a setting
          for rstart). When operating in the Markers Window Limits mode
          (this equals setting xspectrum_window_limits to 1) xspectrum
          generates a spectrum starting at rstart and ending at rend. Then
          the value specified for time, if any, is ignored. When operating
          in the Cursor +- size/2 mode, rstart and rend are ignored.

     Regardless of the Window Limits mode, xspectrum sends a message back to
     xwaves setting the markers to show the window limits used to compute
     the spectrum.

save_spectrum
     OUTPUT SPECTRAL VALUES

     output
          Name of a file to receive the computed spectral values. Output is
          an ASCII file containing header information followed by
          frequency-value pairs, one to a line.

     Only the most recently created ``master'' spectrum can be saved using
     this command. In future releases the spectrum output function will be
     enhanced.

print
     PRINT GRAPHICS

     This outputs the contents of the label display window as PostScript  or
     PCL  to a file or the line printer. The output attributes may be
     established using the xwaves print setup widget as explained in the
     chapter ``Printing Graphics'' of the full manual. The print attributes
     described in ``Printing Graphics'' may also be set as xspectrum
     variables via send commands.

N.B.: The following commands are recognized by the object xspectrum: i.e.
xspectrum is the receiver in the send command.

make
     CREATE A DISPLAY AND/OR GENERATE A SPECTRUM

     name
          name of an xwaves display object to synchronize the displays with.
     file
          the file name (loaded in xwaves) to be analyzed.
     time
          The center of the analysis window. This causes xspectrum to
          generate a spectrum based on a window centered at time with window
          size given by the current setting of size (sec):  in the control
          panel, if rstart and rend are NOT specified. xspectrum sends a
          message back to xwaves setting the markers to show the window
          limits.
     rstart
          The start of an analysis window (must be accompanied by a setting
          for rend).
     rend
          The end of an analysis window (must be accompanied by a setting
          for rstart). When rstart and rend are set in the make command,
          xspectrum_window_limits is automatically set to 1 (Markers).
          xspectrum generates a spectrum based on the data starting at
          rstart and ending at rend. The value specified for time, if any,
          is ignored. xspectrum sends a message back to xwaves setting the
          markers to show the window limits.

     If the display object already exists, then the make command simply
     computes a new spectrum with the indicated parameters.

quit
     EXIT XSPECTRUM

     xspectrum detaches itself from xwaves and removes all of its displays.
     No data is automatically saved.

save_globals
     OUTPUT VALUES OF GLOBAL VARIABLES

     output
          Name of a file to receive the values of the global variables.
          Output is a list of keyword-value pairs in a format suitable for a
          .wave_pro . If output is not specified, stdout is used. The
          current settings of all control panel items are reflected in the
          saved values.

set
     SET GLOBALS FOR USE BY XSPECTRUM

     <any xspectrum variable>
          variables from the list in section 29.2 .

     Multiple items can be set with a single command. Spectra are recomputed
     and the display is updated after any set command. All these items can
     be initialized in the .wave_pro file. For compatibility with previous
     versions of xspectrum, some of these variables are accepted without the
     xspectrum_ prefix. However, use of the shorter forms in .wave_pro files
     is not recommended, as it likely to lead to confusion in the long run.

----------------------------------------------------------------------------

29.2  xspectrum symbols

The following symbols are available for xspectrum. For an explanation of the
type specifiers after the symbols, see table 27.1.

debug_level
     I

     Sets the verbosity of debugging messages.

xspectrum_a_autozoom
     B

     If the value of xspectrum_a_autozoom is nonzero, the display is
     automatically zoomed in amplitude when the horizontal markers are
     moved. Zero disables automatic amplitude zooming.

xspectrum_analysis_type
     I

     Specifies the analysis method as follows:
     0:
          DFT

     1:
          DFTR

     2:
          AUTOC

     3:
          COV

     4:
          BURG

     5:
          MBURG

     6:
          FBURG

     7:
          VBURG

     8:
          STRCOV

     9:
          STRCOV1

     10:
          CEPST

xspectrum_cep_cutoff
     D

     Gives the nominal cutoff frequency (in seconds) for the CEPST analysis
     type.

xspectrum_cep_liftering
     I

     Selects liftering operation for the CEPST analysis type:
     0:
          None
     1:
          Lowpass
     2:
          Highpass

     When none is selected, the CEPST method is equivalent to the DFT
     method.

xspectrum_cep_trans
     D

     Gives the duration of the frequency transition region (in seconds) for
     the CEPST analysis type.

xspectrum_ctlwin_x
     I

     The x position of the xspectrum control window.

xspectrum_ctlwin_y
     I

     The y position of the xspectrum control window.

xspectrum_datwin_forward
     I

     If non-zero (default), the xspectrum plot window will be brought to the
     foreground every time a new spectrum is computed.

xspectrum_datwin_height
     I

     The height of the xspectrum data plot window (pixels). If this value is
     greater than or equal to 0, upon resize of a spectrum display window
     the new height will become the value of this symbol. This has the
     effect that if a spectrum display window opened for a new display
     object is opened, it will automatically take the height of the last
     resized spectrum display window.

xspectrum_datwin_width
     I

     The width of the xspectrum data plot window (pixels). If this value is
     greater than or equal to 0, upon resize of a spectrum display window
     the new width will become the value of this symbol. This has the effect
     that if a spectrum display window opened for a new display object is
     opened, it will automatically take the width of the last resized
     spectrum display window.

xspectrum_datwin_x
     I

xspectrum_datwin_y
     I

     If there is only one display object, these two globals control the
     initial position of the xspectrum data plot window. Positive values for
     xspectrum_datwin_x or xspectrum_datwin_y specify respectively the X and
     Y position of the xspectrum plot window. If there is more than one
     display object, the xspectrum plot window is aligned with the first
     display window of the corresponding xwaves display object, with the
     xspectrum display directly underneath the left side of the xwaves
     window. If xspectrum_datwin_x is negative, the tops of all xspectrum
     plot windows are positioned directly underneath the first xwaves
     display window of the corresponding object. If xspectrum_datwin_y is
     negative, the left side of all xspectrum windows are lined up
     (vertically) with the left side of the first xwaves display of the
     corresponding object.

xspectrum_f_autozoom
     B

     If nonzero, the display is automatically zoomed in frequency when the
     vertical markers are moved. Zero disables automatic frequency zooming.

xspectrum_formants
     I

     Toggles printing of formant estimates (for LPC-based analysis types):
     0:
          off
     1:
          on

xspectrum_harmonic_cursors
     I

     Toggles whether harmonic cursors are used:
     0:
          off
     1:
          on

xspectrum_horiz_cursors
     I

     Toggles the plotting of horizontal lines at the level corresponding to
     the current frequency selected by the cursor:
     0:
          off
     1:
          on

xspectrum_inv_filt_dur
     D

     Gives the size of the region over which to perform inverse filtering.

xspectrum_inv_filt_integ
     D

     Gives the integration coefficient for inverse filtering.

xspectrum_lpc_order
     I

     Gives the order for LPC-based (maximum entropy) analysis types.

xspectrum_max_fft_size
     I

     Maximum allowable FFT size for use by the DFT and CEPST Analysis type
     item. This has no effect on the DFTR item. Any positive integer greater
     than 512 is acceptable, but it may be possible to exceed the UNIX
     system swap space (or the life of your computer) if unreasonably large
     values are used.

xspectrum_max_lpc_order
     I

     This is the maximum LPC (maximum entropy) order that xspectrum is
     allowed to use when computing reflection coefficients. The limit is
     enforced on the xspectrum control panel. The value must be less than or
     equal to 200.

xspectrum_plot_scale
     I

     Specifies the plotting scale as follows:
     0:
          log pwr (dB)
     1:
          magnitude
     2:
          power (sq. mag.)

xspectrum_preemp
     D

     Gives the preemphasis coefficient.

xspectrum_range_db
     I

     Specifies the extent, in dB, of the vertical axis when the plot scale
     is log pwr (dB) and automatic zooming in amplitude is not in effect.

xspectrum_reference_level
     D

     This is taken to be the 0 dB level when displaying spectra. The
     spectrum dB reticle and numeric cursor readout values are adjusted
     accordingly. It is only effective for the ``log pwr (dB)'' scale mode.
     This variable can be set either explicitly or via the menu option in
     the xspectrum display window.

xspectrum_reticle
     I

     Turns the reticle on or off, with:
     0:
          off
     1:
          on

xspectrum_window_limits
     I

     Determines whether window limits are determined by the size (sec):
     entry in the control panel centered on the cursor Cursor +- size/2 (if
     0) or by the current xwaves left and right marker positions (Marker; if
     1).

xspectrum_window_size
     D

     Gives the size of the analysis window (when in Cursor +- size/2 mode,
     not Marker mode).

xspectrum_window_type
     I

     Gives the type of shaping window to be applied to the analysis data,
     with:
     0:
          rectangular
     1:
          Hamming
     2:
          Cos^4
     3:
          Hanning

----------------------------------------------------------------------------

Chapter 30

xmarks reference

This chapter contains only a description of commands for xmarks. xmarks does
not have a symbol set of its own. For a full description of file formats and
menu items see the chapter ``xmarks'' of the full manual.

xwaves can be controlled by a command file or by commands from the
send_xwaves facility. Commands from these sources may be passed through to
xmarks via the xwaves send  command (see the chapter ``The waves+ Command
Language'' of the full manual and section 26.2).

The syntax of the sending commands is:

     waves send function xmarks op <command for xmarks>

The syntax of the received commands is:

     receiver command [keyword value] [keyword value] ...

(the same as for xwaves commands). Except where otherwise noted, the first
item, receiver, should be the attachment name xmarks. The second item,
command, is the actual command name.

The following commands are recognized by xmarks:

make
     CREATE AN OBJECT FOR XMARKS

read
     READ LABELS FROM FILE

     file
          name of the file from which the labels are to be read.

write
     WRITE LABELS TO FILE

     file
          name of the file to which the labels are to be written.

N.B.: The following command is recognized by the display object; i.e. the
receiver has the name of the object being marked.

mark
     APPLY OR REPOSITION A TIME LABEL

     time
          the time (in seconds) at which to apply the label.

----------------------------------------------------------------------------

Chapter 31

xchart reference

This chapter contains only a description of commands for xchart. xchart does
not have a set of specific symbols that are not common to xlabel symbols.
For a full description of file formats and menu items see the chapters
``xlabel'' and ``xchart'' of the full manual.

xwaves can be controlled by manually entered commands, commands in a command
file or, when running in the server mode, by commands from the send_xwaves
facility. Commands from these sources may be passed through to xchart via
the xwaves send  command (see the chapter ``The waves+ Command Language'' of
the full manual and section 26.2). The syntax of the sending commands is:

     waves send function xchart op <command for xchart>

The syntax of the received commands is:

     receiver command [keyword value] [keyword value] ...

(the same as for xwaves commands). The first item, receiver, is either the
attachment name xchart or the name of a display object. The second item,
command, is the actual command name.

xchart is an extension of the xwaves attachment xlabel . It is a proper
superset of xlabel, in that it offers all of the features of xlabel and
provides an additional display mode. Please refer to the chapters ``xlabel''
and ``xchart'' of the full manual for a complete description of using xchart
and xlabel under control of command files and shell scripts. The two
commands specific to xchart should be sent to the object xchart.

kill
     REMOVE ALL OR PART OF A DISPLAY OBJECT

     name
          (see the xlabel kill command).
     file
          (see the xlabel kill command).
     chartfile
          the name of the chart-file to be removed from the display. Only
          one file or chartfile can be specified for each kill invocation.

     This command does not allow you to select chart displays to be
     destroyed. If file is not specified, all the display windows in the
     object, including the chart file display windows, will be removed.
     Otherwise just the selected label file display window will be removed.
     The only way to selectively unload chart files is via the menu item
     that corresponds to *UNLOAD*.

make
     MAKE A NEW FILE, OR LOAD AN EXISTING FILE

     file or labelfile
          label file pathname to be displayed or created.
     chartfile
          the pathname of an existing chart file to be displayed.
     color
          colormap entry to use for the segment boundary marks (new label
          files only). Numbers in the range of 115-125 are best.
     name
          name of an xwaves display object with which to time synchronize.
     signal
          a particular signal in the display object. If signal is omitted,
          the chart/label window will always attach to the most recently
          displayed signal. If it is included, the chart/label window will
          remain stuck to the specified xwaves signal display.
     menufile
          UNIX path name of the menu to be associated with the label file
          display. This may be changed at any time while labeling. Also set
          using Label Menu File:  in control panel.
     chartmenu
          UNIX path name of the menu to be associated with the chart file
          display. This must be set when a chartfile is loaded, or, via the
          set command, before chart files are loaded.
     label_height
          height in pixels of the display area for each label file in the
          display window.
     font
          the font to be used when displaying the labels in the data window.
          Any of the fonts from the listing generated by xlsfonts are
          acceptable. Note that if the font is also specified in the
          labelmenu file, the latter overrides.
     fields or active_fields
          same as fields under activate and Active fields:  in control panel
          (see the xlabel manual sections).

----------------------------------------------------------------------------

Chapter 32

xwaves quick reference

This chapter lists all the xwaves commands and their parameters and the
xwaves symbols. For more information refer to the chapter ``The waves+
command language'' of the full manual and to the chapters 26 and 27.

The basic syntax for invoking simple xwaves commands is:

     object command [keyword value] [keyword value] ...

object
     name of the object to which the command is directed
command
     name of the command to be executed
keyword
     name of some argument that the command recognizes
value
     value of the corresponding argument

----------------------------------------------------------------------------

   32.1  xwaves commands
         32.1.1  xwaves global commands
         32.1.2  xwaves object commands
         32.1.3  xwaves built-in commands
   32.2  xwaves symbols
         32.2.1  Global symbols
         32.2.2  Objebct symbols

----------------------------------------------------------------------------

32.1  xwaves commands

----------------------------------------------------------------------------

   32.1.1  xwaves global commands
   32.1.2  xwaves object commands
   32.1.3  xwaves built-in commands

----------------------------------------------------------------------------

32.1.1  xwaves global commands

For xwaves global commands, the syntax is the following, with the object
waves being optional:

     waves command [keyword value] [keyword value] ...

List of Global commands and their parameters

add_espsf
     out_ext display outputs name op command
add_espsn
     name op command menu
add_espst
     name op command menu
add_op
     name op command menu
add_op_panel
     help_file loc_x loc_y show_vars show_ops
add_waves
     name op command menu builtin submenu
attach
     function
auto_plot_limits

branch
     commandname
call
     commandname
cd
     path
close_ctlwin
     invisible
close_panel
     name invisble
delete_all_items
     menu
delete_item
     name menu
detach
     function
disable_rpc

disable_server

enable_rpc

enable_server

get
     return_id file function attributes aname output
key_map
     command op menu key
key_unmap
     command op menu key
kill
     file name
kill_panel
     name
make
     file name loc_x loc_y height width (and all global variables)
make_panel
     file name panel_choice choice_horiz title icon_title columns
     quit_button
open_ctlwin

open_panel
     name
print_setup

quit

return

save_add_ops
     output
save_keymaps
     output
save_menus
     output menu
save_panels
     output
send
     versnum prognum function op command
set
     all da_location (and all global variables)
setenv
     variable value
shell

sleep
     seconds

----------------------------------------------------------------------------

32.1.2  xwaves object commands

For xwaves object commands, the syntax is the following, with the object
being the name of the current object or ``.'':

     object command [keyword value] [keyword value] ...

List of Object commands and their parameters

activate
     identifiers numbers file op
align
     file
bracket
     end start file
close
     file invisible
colormap
     range threshold image_range image_clip file
cursor
     frequency yval time
get
     return_id file function attributes aname output
mark
     color time
marker
     do_left time
op
     file command op c_chan c_yval c_time
open
     file
overlay
     file on_file
page
     ref_step step file
play
     end start file
play_wind
     file
print_ensemble

print_graphic
     file
save
     end outputname start file
set
     (all global symbols and all object symbols that are settable)
spectrogram
     end start output type loc_x loc_y image_range image_clip
unmark
     color time all

----------------------------------------------------------------------------

32.1.3  xwaves built-in commands

Builtin commands are a special case of xwaves object commands and cannot be
used in the ``normal'' way with the send_xwaves (1-ESPS) command or issued
from the COMMAND (or @file) field or an xwaves command file. In order to use
these commands from outside the menu you have to use the object command op .
See section 26.4 for further details. The basic syntax you need to use to
invoke the builtin commands is:

     object op file filename op built-in-command-name

List of Builtin Object commands

   * play between marks
   * play window contents
   * play entire file
   * play to end of file
   * page ahead
   * page back
   * window ahead
   * window back
   * align&rescale
   * bracket markers
   * zoom in
   * zoom out
   * zoom full out
   * spectrogram (W.B.)
   * spectrogram (N.B.)
   * save segment in file
   * delete segment
   * insert file
   * button modes
   * kill window
   * print graphic
   * print ensemble

----------------------------------------------------------------------------

32.2  xwaves symbols

----------------------------------------------------------------------------

   32.2.1  Global symbols
   32.2.2  Objebct symbols

----------------------------------------------------------------------------

32.2.1  Global symbols

This list is in alphabetical order, except that globals now considered
obsolete or quite arcane are listed in a group at the end.

List of Global symbols for xwaves

   * append_extensions
   * attachments
   * blowup_op
   * c_range_offset
   * colormap
   * command_step
   * commandname
   * ctlwin_iconized
   * ctlwin_x
   * ctlwin_y
   * cross_level
   * debug_level
   * def_header
   * do_color
   * dont_save_sgrams
   * edit_ganged
   * ens_print_atts
   * f0_min
   * f0_plot_specs
   * f0_range
   * f0_size
   * first_x
   * find_crossing
   * first_y
   * funcname
   * h_spect_rescale
   * image_clip
   * image_range
   * init_file
   * inputname
   * invert_dither
   * left_op
   * line_type
   * max_buff_size
   * middle_op
   * min_spec_height
   * min_spec_width
   * nb_spect_params
   * objectname
   * objects
   * output_dir
   * outputname
   * overlay_as_number
   * overlayname
   * play_prog
   * plot_max
   * plot_min
   * print_graphic_command
   * print_graphic_file
   * print_graphic_orientation
   * print_graphic_printer
   * print_graphic_resolution
   * print_graphic_scale
   * print_graphic_type
   * print_only_plot
   * readout_bar_height
   * redraw_on_release
   * ref_size
   * ref_start
   * ref_step
   * remote_input_path
   * remote_output_path
   * remote_path
   * reticle_grid
   * rewrite_after_edit
   * s_range_offset
   * samp_range_prefix
   * scroll_ganged
   * scrollbar_height
   * sgram_prog
   * shorten_header
   * show_labels
   * show_processes
   * show_vals
   * sig_max_override
   * socket_port
   * spec_left_op
   * spec_middle_op
   * spect_interp
   * spect_rescale_scope
   * temp_path
   * time_range_prefix
   * use_dsp32
   * v_spect_rescale
   * verbose
   * wave_height
   * wave_width
   * wb_spect_params
   * x_increment
   * y_increment
   * zoom_ganged
   * zoom_ratio
   * ARIEL_16
   * ARIEL_HK
   * dsp32_wait
   * fea_sd_special
   * options
   * P8574_type
   * write_common

----------------------------------------------------------------------------

32.2.2  Object symbols

----------------------------------------------------------------------------

Gettables

List of gettable view-specific symbols

   * b_marker_chan
   * b_marker_yval
   * cursor_channel
   * cursor_channels
   * cursor_samp
   * cursor_label
   * cursor_time
   * cursor_value
   * cursor_values
   * cursor_yval
   * dur_samp
   * dur_seconds
   * dur_time
   * file
   * files
   * height
   * is_iconized
   * l_mark_samp
   * l_mark_time
   * l_marker_samp
   * l_marker_samp_from_start
   * l_marker_time
   * lmsfs
   * loc_x
   * loc_y
   * mark_range_samp
   * mark_range_time
   * mark_reference
   * name
   * new_files
   * object_commands
   * objects
   * operators
   * overlays
   * r_mark_samp
   * r_mark_time
   * r_marker_samp
   * r_marker_time
   * range_chan
   * range_samp
   * range_time
   * range_yval
   * sec/cm
   * settables
   * t_marker_chan
   * t_marker_yval
   * val/cm
   * variables
   * view_channels
   * view_end_time
   * view_end_yval
   * view_start_time
   * view_start_yval
   * waves_commands
   * width

----------------------------------------------------------------------------

Settables

List of settable view-specific symbols

   * b_marker_chan
   * b_marker_yval
   * background
   * channels
   * cursor_channel
   * cursor_time
   * cursor_yval
   * edit_ganged
   * file
   * h_rescale
   * invert_dither
   * l_marker_time
   * left_op
   * line_color
   * line_type
   * mark_reference
   * middle_op
   * move_op
   * overlay_as_number
   * page_step
   * plot_max
   * plot_min
   * r_marker_time
   * readout_bar_height
   * redraw_on_release
   * rescale_scope
   * reticle_on
   * rewrite_after_edit
   * scroll_ganged
   * scrollbar_height
   * shorten_header
   * show_labels
   * show_vals
   * spect_interp
   * t_marker_chan
   * t_marker_yval
   * v_rescale
   * value_offset
   * value_scale
   * zoom_ganged
   * zoom_ratio

----------------------------------------------------------------------------

Chapter 33

xlabel quick reference

This chapter lists all the commands and symbols for xlabel. No further
explanation is given. For more information see the comprehensive reference
part of the full manual, or the introductory chapters. See chapter 28.

----------------------------------------------------------------------------

   33.1  xlabel command reference
   33.2  xlabel symbols

----------------------------------------------------------------------------

33.1  xlabel command reference

The following commands may be sent to xlabel via the xwaves send  command.
The basic syntax is:

     waves send function xlabel op <command for xlabel>

The format for commands to xlabel is:

     xlabel command [keyword value] [keyword value] ...

List of commands for xlabel

activate
     file name fields
kill
     name file
labelfile
     (see make)
labelmenu
     menufile name file
make
     labelfile file color name signal menufile label_height font fields
mark
     color file label replace_field time
print

quit

save_globals
     output
set
     (any xlabel variable)
unload
     name file

----------------------------------------------------------------------------

33.2  xlabel symbols

The following symbols are available to control the behavior of xlabel.

List of symbols for xlabel

   * xlabel_ctlwin_x
   * xlabel_ctlwin_y
   * xlabel_fields
   * xlabel_font
   * xlabel_frame_hoff
   * xlabel_frame_voff
   * xlabel_insert_mode
   * xlabel_labelfile
   * xlabel_label_height
   * xlabel_menufile
   * xlabel_name

----------------------------------------------------------------------------

Chapter 34

xspectrum quick reference

This chapter lists all the commands and symbols for xspectrum. No further
explanation is given. For more information see the comprehensive reference
part of the full manual, or the introductory chapters. See chapter 29.

----------------------------------------------------------------------------

   34.1  xspectrum command reference
   34.2  xspectrum symbols

----------------------------------------------------------------------------

34.1  xspectrum command reference

The following commands may be sent to xspectrum via the xwaves send
command. The basic syntax is:

     waves send function xspectrum op <command for xspectrum>

The format for commands to xspectrum is:

     xspectrum command [keyword value] [keyword value] ...

List of commands for xspectrum

kill

mark
     file time rstart rend
save_spectrum
     output
print

make
     name file time rstart rend
quit

save_globals
     output
set
     (any xspectrum variable)

----------------------------------------------------------------------------

34.2  xspectrum symbols

The following symbols are available to control the behavior of xspectrum.

List of symbols for xspectrum

   * debug_level
   * xspectrum_a_autozoom
   * xspectrum_analysis_type
   * xspectrum_cep_cutoff
   * xspectrum_cep_liftering
   * xspectrum_cep_trans
   * xspectrum_ctlwin_x
   * xspectrum_ctlwin_y
   * xspectrum_datwin_forward
   * xspectrum_datwin_height
   * xspectrum_datwin_width
   * xspectrum_datwin_x
   * xspectrum_datwin_y
   * xspectrum_f_autozoom
   * xspectrum_formants
   * xspectrum_harmonic_cursors
   * xspectrum_horiz_cursors
   * xspectrum_inv_filt_dur
   * xspectrum_inv_filt_integ
   * xspectrum_lpc_order
   * xspectrum_max_fft_size
   * xspectrum_max_lpc_order
   * xspectrum_plot_scale
   * xspectrum_preemp
   * xspectrum_range_db
   * xspectrum_reference_level
   * xspectrum_reticle
   * xspectrum_window_limits
   * xspectrum_window_size
   * xspectrum_window_type

----------------------------------------------------------------------------

Chapter 35

xmarks quick reference

This chapter lists all the commands for xmarks. No further explanation is
given. For more information see the comprehensive reference part of the full
manual, or the introductory chapters. See chapter 30.

The basic syntax is:

     waves send function xmarks op <command for xmarks>

The format for commands to xmarks is:

     xmarks command [keyword value] [keyword value] ...

List of commands for xmarks

make
     name
read
     file
write
     file
mark
     time

----------------------------------------------------------------------------

Chapter 36

xchart quick reference

This chapter lists the commands and symbols for xchart that are new in
comparison to xlabel. No further explanation is given. For more information
see the comprehensive reference part of the full manual, or the introductory
chapters. See chapter 31.

----------------------------------------------------------------------------

   36.1  xchart command reference
   36.2  xchart symbol reference

----------------------------------------------------------------------------

36.1  xchart command reference

The commands for xchart are a superset of the commands for xlabel. This
chapter gives only the new commands. The following commands may be sent to
xchart via the xwaves send  command in addition to the commands for xlabel.
The basic syntax is:

     waves send function xchart op <command for xchart>

The format for commands to xchart is:

     xchart command [keyword value] [keyword value] ...

List of commands for xchart

kill
     name file chartfile
make
     file chartfile color name signal menufile chartmenu label_height font
     fields

For the other commands see chapter 33.

----------------------------------------------------------------------------

36.2  xchart symbol reference

See chapter 33.

----------------------------------------------------------------------------

Chapter 37

Glossary

This chapter describes the terminology used in the xwaves manual (and this
reference guide).

attachments :
     A program that communicates with xwaves to perform specific tasks.
     These programs are separate UNIX programs, but they cannot be run
     without xwaves running. Currently there are 4 attachments: xlabel,
     xspectrum, xmarks, and xchart. The attachments have a command language
     of their own. Commands can be sent to them via the xwaves send command.
boolean :
     In the context of xwaves variable assignments, a boolean is FALSE  if
     it has the value 0 and TRUE  if it has any non-zero value.
commands :
     Commands are members of a distinguished, permanent set of character
     strings (with no embedded spaces) that provides a means for controlling
     xwaves from other programs, or via typed lines in the xwaves main
     control panel. These commands may also be associated with buttons on
     xwaves button panels. xwaves commands are divided into two categories:
     ``global'' or ``waves'' commands and ``object'' commands. waves
     commands are sent to the program xwaves itself and cause some
     program-wide impact. View or object commands are sent to a particular
     display window of a display object and usually perform operations that
     have impact only on the display window or its object. The op command
     provides command-type access to operators (see below). See chapter 26
     for further details. See also below under object commands and waves
     commands.
cursors :
     These are the lines on data display windows that move when the mouse
     pointer is inside of the frame of a display window. For a given display
     object, the cursor representations in all display window are linked so
     that moving the pointer in one display window, causes all data cursors
     to move in step in both time and amplitude (frequency) domains.
     Cursors, marks and markers may be positioned independently in each data
     object.
display object, data object (or object) :
     Set of display windows opened under the same ``object'' name. The
     object name is specified in the waves+ commands that are used to create
     display windows. The object name defaults to the name in the OBJECT
     name: field in the Main Control Panel if not explicitly specified when
     creating the display window.

     All windows in a display object share the same set of marks and markers
     and have their time/frequency/amplitude cursors synchronized.
display window :
     A single window which is either an image or a waveform window.
external process (or program) :
     This term refers to any program that works in conjunction with xwaves
     to accomplish your goal. A major mode for functional extension of
     xwaves is calling other programs from xwaves menus, button panels, etc.
     to compute some result that itself may then become an xwaves data
     display window. Many ESPS programs can serve in this capacity, but also
     programs and shell scripts written by yourself or others.
image window :
     A window that displays spectrogram-like plots. Records are displayed
     horizontally, and tracks(channels) are displayed vertically. Color is
     used to differentiate between amplitude values in the tracks of the
     signal displayed.
markers :
     Each data display window has four markers, referred to as top, bottom,
     left and right. These may be moved in the display window by a variety
     of means, including using the mouse pointer and buttons. The marker
     positions in a display window are indicated by dashed lines extending
     all of the way across the display window. The left and right markers
     are often referred to as the vertical markers. The top and bottom ones
     are the horizontal markers. Many xwaves operators perform their
     functions on the region of data delimited by the markers. Marker
     positions are displayed consistently in all display windows comprising
     a data object. See the section ``Marking Segments'' of the full manual.
marks :
     Each display object may have a collection of time ``marks'' on the
     displays. These may be placed anywhere in time and may have any color
     you choose. They have no ``built-in'' meaning to xwaves, but you have
     access to their attributes via symbols in the add_op command. Thus, you
     may construct custom operators based on the locations of these marks.
     Attachments, like xlabel, xchart and xmarks, use xwaves' mark facility
     to represent the segment boundaries which these attachments manage. You
     can place marks using the mark  command. See section 26.4 or 27.3. Note
     the difference between markers and marks.
menu-operator lists :
     These are named lists, maintained by xwaves and possibly augmented by
     you, that associate names with operations. xwaves comes with some menu
     operators defined. These are the default data display window menus you
     see when xwaves runs with no customization. The add_op  command,
     described in detail in section 26.2, permits definition of custom
     operators. There are three distinguished list names: wave, for
     operators that may appear on menus of waveform data display windows,
     spect, for operators that may appear on spectrogram display window
     menus, and all, for operators that can appear on all data display
     window menus. The add_op command allows generation of other named lists
     (with the menu specification). Operators defined on any of these other
     lists are accessible for many purposes, but will never appear on any
     data display window menu.
object :
     See under display object.
object commands :
     These commands are always explicitly directed to an existing display
     object by having the object name be the first word on the command line.
     View commands cannot be issued if no display object exists. See the
     chapter ``The waves+ Command Language'' of the full manual.
operators :
     Operators are the functions xwaves knows of. xwaves knows about
     functions either because they are built-in or because they have been
     defined through the add_op  command. Operators implement the functions
     invoked when menu items are selected from data display window menus.
     They also implement functions that may be directly bound to keys on the
     keyboard. Many operators perform their function on the region of a
     signal delimited by the left, right, top and bottom data display window
     markers. Internal to xwaves, operators exist on menu-operator lists
     that may be augmented or modified by using the add_op command. New
     operator definitions can be comprised of xwaves commands,
     externally-called programs, or both. See the add_op command in section
     26.2.
pointer :
     This refers to the arrow, or similar figure used to indicate the active
     position of the mouse on the window display screen. When this pointer
     enters an xwaves data display window, it begins to move the xwaves
     cursors. In general this also fronts the window (unless you changed
     specific X resources).
quoted string :
     In several contexts this term comes up to describe the type of
     character string that may be used (e.g. as the name of a menu item). A
     quoted string may simply be written verbatim if:
       1. it contains no blanks,
       2. it does not start with a double quote ",
       3. it contains blanks (embedded spaces), but is the last item on a
          command line.
     Otherwise, enclose the string in double quotes. Between the delimiting
     double quotes, use the pair reverse-slash double-quote (to denote a
     double quote character that is to be part of the string). In the same
     context, use a pair of reverse slashes (\\) to denote a single reverse
     slash character.
reticle :
     This refers to the tic-marks, grid lines, borders and numeration that
     are optional decoration on xwaves' data display windows. The resolution
     of the reticles adjusts as the display window is resized or zoomed so
     as to maintain a reasonable density of marks and numbers.
scrollbars :
     At the top of each xwaves data display window is a horizontal region we
     refer to as the scrollbar. It is mouse sensitive and may be moved in
     various ways by pressing the left, middle and right mouse buttons.
     (Strictly speaking, these operations are ``jumping'' rather than
     ``scrolling'', but the used paradigm is the same as the ``scrollbars''
     typical of text displays in various other X applications).
simple quoted string :
     A simple quoted string is similar to a quoted string with one
     exception: In the case where multiple space-separated items are present
     without an open double quotes, the simple quoted string type assumes
     that only the first item is the argument, whereas the quoted string
     type assumes the remainder of the line is the argument. Simple quoted
     strings are used to represent, among other things, menu item names
     which may consist of single or multiple words.
view :
     Word used in commands to refer to display window.
waveform window :
     A window that displays two-dimensional signals, possibly with multiple
     channels. The horizontal axis represents time, the vertical a scalar
     value.
waves commands :
     These are commands directed at the program xwaves itself. Formally,
     such commands should always begin with the word waves. However, this
     requirement is relaxed for convenience, so that if the xwaves' command
     interpreter is sent a string that does not begin with the name of any
     object known to it (these include waves and any current display
     object), it assumes the command was destined for the object waves, i.e.
     the program itself. See the chapter ``The waves+ Command Language'' of
     the full manual.

----------------------------------------------------------------------------